MIR-Pump NIR-Probe Fiber-Optic Photothermal Spectroscopy With Background-Free First Harmonic Detection

Chenyu Yao,Shoufei Gao,Yingying Wang,Pu Wang,Wei Jin,Wei Ren
DOI: https://doi.org/10.1109/JSEN.2020.3000795
IF: 4.3
2020-01-01
IEEE Sensors Journal
Abstract:We demonstrated MIR-pump NIR-probe photothermal spectroscopy with the first harmonic (PTS- <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$1{f}$ </tex-math></inline-formula> ) detection of formaldehyde, one of the most common volatile organic compounds (VOCs), in a silica hollow-core negative curvature fiber (HC-NCF). The photothermal gas sensor adopts a mid-infrared interband cascade pump laser at <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$3.6~\mu \text{m}$ </tex-math></inline-formula> and a near-infrared fiber probe laser at <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$1.56~\mu \text{m}$ </tex-math></inline-formula> . At the optimal modulation frequency (8 kHz) and modulation index (1.8) of the pump laser, we obtained a normalized noise equivalent absorption (NNEA) coefficient of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$4\times 10^{-9}$ </tex-math></inline-formula> cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">−1</sup> WHz <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$^{-1/2}$ </tex-math></inline-formula> . The use of HC-NCF with an inner diameter of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$65~\mu \text{m}$ </tex-math></inline-formula> enables the sensitive photothermal detection even for a very low pump power of micro-watts. The background-free PTS- <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$1{f}$ </tex-math></inline-formula> detection was observed to enhance the sensitivity by a factor of 2.4 compared to the second harmonic ( <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$2{f}$ </tex-math></inline-formula> ) detection. A theoretical model was established in this work to interpret the experimental results.
What problem does this paper attempt to address?