Real time pH measurements in the intact rat conceptus using ultramicrofiber-optic sensors

WH Tan,BA Thorsrud,C Harris,R Kopelman
DOI: https://doi.org/10.1021/bk-1998-0690.ch022
1998-01-01
Abstract:Real time measurements of pH have been made in single, viable, intact rat conceptuses during the period of organogenesis, using newly developed ultramicrofiberoptic chemical sensors. The fiberoptic sensors are constructed using a novel technology based on photo-nanofabrication of optical probes and near-field photochemical synthesis. The pH sensors are a thousandfold smaller, with a millionfold reduction in necessary sample size, and show at least a hundredfold reduction in response time, when compared to other optical sensors currently available. In the present application, biosensors are inserted into the extraembryonic fluid (EEF) compartment of an intact rat conceptus, which is positioned in a customized perifusion chamber. Viability is maintained and exposures are controlled during pH determinations, while causing no damage to or leakage of fluid from the surrounding visceral yolk sac (VYS). Static determinations of pH in intact rat conceptuses of varying gestational ages showed decreasing pH with conceptal age. Dynamic alterations in pH were also measured in response to several variations in environmental conditions and specifically during exposure to a cellular thiol oxidant, diamide.