Extracellular pH mapping of liver cancer on a clinical 3T MRI scanner
Daniel Coman,Dana C. Peters,John J. Walsh,Lynn J. Savic,Steffen Huber,Albert J. Sinusas,MingDe Lin,Julius Chapiro,R. Todd Constable,Douglas L. Rothman,James S. Duncan,Fahmeed Hyder
DOI: https://doi.org/10.1002/mrm.28035
2019-11-05
Magnetic Resonance in Medicine
Abstract:<section class="article-section__content"><h3 class="article-section__sub-title section1"> Purpose</h3><p>To demonstrate feasibility of developing a noninvasive extracellular pH (pH<sub>e</sub>) mapping method on a clinical MRI scanner for molecular imaging of liver cancer. </p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Methods</h3><p>In vivo pH<sub>e</sub> mapping has been demonstrated on preclinical scanners (e.g., 9.4T, 11.7T) with Biosensor Imaging of Redundant Deviation in Shifts (BIRDS), where the pH<sub>e</sub> readout by 3D chemical shift imaging (CSI) depends on hyperfine shifts emanating from paramagnetic macrocyclic chelates like TmDOTP<sup>5−</sup> which upon extravasation from blood resides in the extracellular space. We implemented BIRDS‐based pH<sub>e</sub> mapping on a clinical 3T Siemens scanner, where typically diamagnetic <sup>1</sup>H signals are detected using millisecond‐long radiofrequency (RF) pulses, and <sup>1</sup>H shifts span over ±10 ppm with long transverse (<i>T</i><sub>2</sub>, 10<sup>2</sup> ms) and longitudinal (<i>T</i><sub>1</sub>, 10<sup>3</sup> ms) relaxation times. We modified this 3D‐CSI method for ultra‐fast acquisition with microsecond‐long RF pulses, because even at 3T the paramagnetic <sup>1</sup>H shifts of TmDOTP<sup>5−</sup> have millisecond‐long <i>T</i><sub>2</sub> and <i>T</i><sub>1</sub> and ultra‐wide chemical shifts (±200 ppm) as previously observed in ultra‐high magnetic fields. </p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Results</h3><p>We validated BIRDS‐based pH in vitro with a pH electrode. We measured pH<sub>e</sub> in a rabbit model for liver cancer using VX2 tumors, which are highly vascularized and hyperglycolytic. Compared to intratumoral pH<sub>e</sub> (6.8 ± 0.1; <i>P</i> < 10<sup>−9</sup>) and tumor's edge pH<sub>e</sub> (6.9 ± 0.1; <i>P</i> < 10<sup>−7</sup>), liver parenchyma pH<sub>e</sub> was significantly higher (7.2 ± 0.1). Tumor localization was confirmed with histopathological markers of necrosis (hematoxylin and eosin), glucose uptake (glucose transporter 1), and tissue acidosis (lysosome‐associated membrane protein 2). </p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Conclusion</h3><p>This work demonstrates feasibility and potential clinical translatability of high‐resolution pH<sub>e</sub> mapping to monitor tumor aggressiveness and therapeutic outcome, all to improve personalized cancer treatment planning. </p></section>
radiology, nuclear medicine & medical imaging