Xenon oscillation analysis in Monte Carlo burnup calculation

Yaodong Li,Ganglin Yu,Wanlin Li,Zonghuan Chen,Kan Wang
DOI: https://doi.org/10.11884/HPLPB201830.170228
2018-01-01
Abstract:Burnup calculation is one of the core contents in physical analysis of nuclear reactors.In Monte Carlo burnup cal-culation,power oscillation might occur periodically in certain geometrical dimension and certain step length,namely xenon oscilla-tion.Xenon oscillations might result in a serious deviation from the actual situation.The fundamental reason for the xenon oscil-lation is that the neutron flux and xenon concentration in the regions of burn-up do not match.According to the mechanism of xenon oscillation,we classify xenon oscillations as physical xenon oscillations produced in short step conditions and numerical xen-on oscillations produced in long time step conditions.Balanced xenon oscillation suppression method is forced to balance neutron flux with xenon concentration.In the RMC transport the article uses module a balanced xenon method for the calculation of iodine and xenon.In the RMC transport module,the equilibrium xenon method was used to continuously update the concentration of io-dine and xenon.In the case of convergence,the occurrence of xenon oscillation is suppressed.
What problem does this paper attempt to address?