Long Term Success Rate of Catheter Ablation for Ventricular Arrhythmias Originate from Tricuspid Annulus
Chen Qiushi,Fan Baohan,Zhang Fengxiang,Chen Hongwu,Ju Weizhu,Yang Gang,Li Mingfang,Gu Kai,Liu Hailei,Wang Zidun,Yang Bing,Chen Minglong
DOI: https://doi.org/10.3760/cma.j.issn.1007-6638.2019.02.012
2019-01-01
Abstract:Objective This study investigated the long-term success rate of catheter ablation for premature ventricular complex (PVC)and ventricular tachycardia(VT)originating from tricuspid annulus (TA).Methods From January 2013 to December 2016,the data of 43 patients with idiopathic PVC/VT originating from TA were analyzed retrospectively in our center.Three dimensional electroanatomical mapping was used to construct the TA and the right ventricular geometric model.The earliest activation point of PVC/ VT was traced by activation mapping.According to activation mapping,the patients were enrolled into free wall group and septum group.In the patients with PVC/VT originating from free wall and posterior septum,ablation was carried out in a temperature controlled and irrigation mode with the power set to 30-40 W,fluid 17-20 ml/min,temperature set at 43 ℃,and ablation time to 30 seconds/point.If PVC/VT originated from anterior and middle septum,ablation was carried out in a temperature controlled and non-irrigation mode with the power set to 30 W,temperature set at 55 ℃,and ablation time to 30 seconds/point.Follow-up visits were conducted monthly for the first 3 months and then,every 6 months after surgery.12 lead electrocardiogram and 24-hour ambulatory electrocardiogram monitoring were required at each follow-up visit.Results Mapping showed that among the 43 patients with PVC/VT,22 (52.3%)had a free wall (FW),and 21 (47.7%)septal origins.There was no significant difference of activation time at the target site,energy,ablation time,X-ray exposure time and dose between two groups.Ablation temperature was lower in FW group than in septum group [(39.3 ± 6.3) ℃ vs.(43.5 ± 4.7) ℃,P=0.03),however,irrigated flow was higher in FW group than in septum group [(11.9 ± 9.3) ml/min vs.(4.6 ± 8.2) ml/min,P=0.02).Procedure time was longer in septum group than in FW group [(110.4 ± 45.6) min vs.(85.4 ± 27.9) min,P=0.04].Ablation was successful in 39 (90.7%) cases,and the success rate was higher in FW group than in septum group (100% vs.81%,P=0.03).The remaining 4 patients had septal origins,with 2 anterior septum and 2 medial septum.No serious complications such as pericardial tamponade were observed during the operation.The average follow-up was (45.5 ± 14.0) months.PVC recurred in 4 patients:2 patients with posterior free wall,1 with middle free wall,1 with middle septum,and the second ablation were successful in 3 of the patients,the other one refused to accept re-ablation.A 3.8 years' follow-up showed that the success rate of TA-PVC/VT ablation was 81.4%.Conclusion Catheter ablation is a safe and effective method for the treatment of TA-PVC/VT.