Damage Detection in CFRP / GFRP Composite Bar Using Guided Ultrasonic Waves

Y. Wu,W. Zhou,G. Xian
2019-01-01
Abstract:The CFRP/GFRP composite bar is a multilayered cylindrical structure, in which the CFRP bar is embedded in the GFRP. It has some advantages over the single CFRP or GFRP composite bar, however delamination between the CFRP and GFRP may lead to a loss of composite action, resulting in reduction of stiffness and fatigue life of this composite bar. Due to the inaccessibility and invisibility of the interface between CFRP and GFRP, the interfacial performance monitoring using traditional measurement methods have been proved challenging. In this work, the guided ultrasonic wave based method is proposed to detect the delamination in CFRP/GFRP composite bar. Since the guided ultrasonic wave is generated using the circular piezoelectric wafer attached on the end plane of the bar, the shear lag transfer model is presented first for the piezoelectric wafer mounted on the surface of the composite bar. This model can explain the characteristics of the guided wave generated in the core CFRP and outer GFRP. Subsequently, the finite element analyses are implemented to demonstrate the characteristics of the guided wave propagating in CFRP/GFRP composite bar. Finally, a series of experiments are conducted on the real CFRP/GFRP composite bars, which include the pristine and the damaged ones. The guided wave signals obtained in the experiments are used to analyze the degree and location of the delamination. This study provides an appropriate approach for the long CFRP/GFRP composite bar.
What problem does this paper attempt to address?