TVOC and Health in Non-industrial Indoor Environments. Report from a Nordic Scientific Consensus Meeting at Langholmen in Stockholm, 1996
K. Andersson,J. V. Bakke,O. Bjorseth,C.-G. Bornehag,G. Clausen,J. K. Hongslo,M. Kjellman,S. Kjaergaard,F. Levy,L. Molhave,S. Skerfving,J. Sundell
DOI: https://doi.org/10.1111/j.1600-0668.1997.t01-2-00002.x
IF: 6.5539
1997-01-01
Indoor Air
Abstract:Indoor AirVolume 7, Issue 2 p. 78-91 TVOC and Health in Non-industrial Indoor Environments Report from a Nordic Scientific Consensus Meeting at Långholmen in Stockholm, 1996 K. Andersson, K. Andersson National Institute for Working Life, SwedenSearch for more papers by this authorJ. V. Bakke, J. V. Bakke The National Labour Inspectorate, NorwaySearch for more papers by this authorO. Bjørseth, O. Bjørseth Norwegian University of Science and Technology, NorwaySearch for more papers by this authorC.-G. Bornehag, C.-G. Bornehag National Testing and Research Institute, SwedenSearch for more papers by this authorG. Clausen, G. Clausen Laboratory of Indoor Environment and Energy, Technical University of DenmarkSearch for more papers by this authorJ. K. Hongslo, J. K. Hongslo Department of Environmental Medicine, National Institute of Public Health, NorwaySearch for more papers by this authorM. Kjellman, M. Kjellman Department of Paediatrics, University Hospital, Linköping, SwedenSearch for more papers by this authorS. Kjærgaard, S. Kjærgaard Department of Environmental and Occupational Medicine, DenmarkSearch for more papers by this authorF. Levy, F. Levy Ullevaal University Hospital, Oslo, NorwaySearch for more papers by this authorL. Mølhave, L. Mølhave Department of Environmental and Occupational Medicine, DenmarkSearch for more papers by this authorS. Skerfving, S. Skerfving Department of Occupational and Environmental Medicine, Lund University, SwedenSearch for more papers by this authorJ. Sundell, J. Sundell Karolinska Institute, Sweden, National Institute of Public Health, SwedenSearch for more papers by this author K. Andersson, K. Andersson National Institute for Working Life, SwedenSearch for more papers by this authorJ. V. Bakke, J. V. Bakke The National Labour Inspectorate, NorwaySearch for more papers by this authorO. Bjørseth, O. Bjørseth Norwegian University of Science and Technology, NorwaySearch for more papers by this authorC.-G. Bornehag, C.-G. Bornehag National Testing and Research Institute, SwedenSearch for more papers by this authorG. Clausen, G. Clausen Laboratory of Indoor Environment and Energy, Technical University of DenmarkSearch for more papers by this authorJ. K. Hongslo, J. K. Hongslo Department of Environmental Medicine, National Institute of Public Health, NorwaySearch for more papers by this authorM. Kjellman, M. Kjellman Department of Paediatrics, University Hospital, Linköping, SwedenSearch for more papers by this authorS. Kjærgaard, S. Kjærgaard Department of Environmental and Occupational Medicine, DenmarkSearch for more papers by this authorF. Levy, F. Levy Ullevaal University Hospital, Oslo, NorwaySearch for more papers by this authorL. Mølhave, L. Mølhave Department of Environmental and Occupational Medicine, DenmarkSearch for more papers by this authorS. Skerfving, S. Skerfving Department of Occupational and Environmental Medicine, Lund University, SwedenSearch for more papers by this authorJ. Sundell, J. Sundell Karolinska Institute, Sweden, National Institute of Public Health, SwedenSearch for more papers by this author First published: 22 April 2004 https://doi.org/10.1111/j.1600-0668.1997.t01-2-00002.xCitations: 124 13Author to whom correspondence should be addressed at National Testing and Research Institute, Box 857, S-501 15 Boras, Sweden AboutPDF ToolsRequest permissionExport citationAdd to favoritesTrack citation ShareShare Give accessShare full text accessShare full-text accessPlease review our Terms and Conditions of Use and check box below to share full-text version of article.I have read and accept the Wiley Online Library Terms and Conditions of UseShareable LinkUse the link below to share a full-text version of this article with your friends and colleagues. Learn more.Copy URL Abstract Abstract The presence of Volatile Organic Compounds (VOC) in indoor air has in past decades often been associated with adverse health effects such as sensory irritation, odour and the more complex set of symptoms called the Sick Building Syndrome (SBS). More recently, a possible link between the increase in the prevalence of allergies throughout the industrialized areas of the world and exposure to elevated concentrations of VOCs has been suggested. In many cases, the total VOC (TVOC) is used as a measure of the concentration of air pollution and, by extension, as a measure of the health risk in non-industrial buildings. However, the TVOC concept has been questioned for a number of reasons, including the facts that it is an ambiguous concept, that individual VOCs making up the whole can be expected to give rise to different effects in people and that researchers have been using different definitions and interpretations of TVOC. This means that simple addition of the quantities of individual VOCs may not be relevant from a health point of view. Twelve researchers from the Nordic countries have reviewed the literature on VOC/TVOC and health. A search of the literature resulted in the identification of about 1100 articles, of which 120 were selected for further examination. A final review of the articles reduced their number to 67 that contained data on both exposure and health effects. The group concluded that indoor air pollution including VOC is most likely a cause of health effects and comfort problems in indoor environments in non-industrial buildings. However, the scientific literature is inconclusive with respect to TVOC as a risk index for health and comfort effects in buildings. Consequently, there is at present an inadequate scientific basis on which to establish limit values/guidelines for TVOC, both for air concentrations, and for emissions from building materials. The group concluded that continued research is required to establish a risk index for health and comfort effects for VOC in non-industrial buildings. References Andersson, S., Sverdrup, C. and GrantéAn, J. (1992) Klimatet i Den Inre MiljöUn, Stockholm Byggforskiningsrådet (8800629) Baird, J., Berglund, B., Berglund, U., Nicander-Bredberg, H. and Noma, E. (1987) “Distinguishing between healthy and sick preschools by chemical classification”, Environment International, 13, 167– 174. Bælum, J., Lundqvist, G., Mølhave, L. and Andersen, N. (1990) “Human response to varying concentrations of toluene”, International Archives of Occupational Environment and Health, 62, 65– 71. Bener, A., Gomes, J. and Hamouda, M. (1996) “Hypertension among workers occupationally exposed to hydrocarbons and organic solvents”, Journal of Environmental Science and Health, A31(2), 291– 303. Berglund, B. (1988) “ Pattern analysis and psychochemistry of air”. In: The Use of QSAR for Chemicals Screening: Limitations and Possibilities, Stockholm , National Chemical Inspectorate, pp. 31– 51 (KEMI Report No. 8). Berglund, B., Johansson, L, Lindvall, T. and Lundin, L. (1989) “ Air quality and symptoms in a sick library building with a return-air ventilation system”. In: Proceedings of Clima 2000, Amersfoort , Netherlands , REHVA, Vol. III, pp. 13– 18. Berglund, B., Johansson, L, Lindvall, T. and Lundin, L. (1990) “ A longitudinal study of perceived air quality and comfort in a sick library building”. In: D.S. Walkinshaw (ed.) Proceedings of Indoor Air '90, Ottawa , Canada Mortgage and Housing Corporation, Vol. 1, pp. 489– 494. Berglund, B., Berglund, U. and Engen, T. (1992) “Can sick buildings be assessed by testing human performance in field experiments?”, Environment International, 18, 221– 229. Berglund, B. and Esfandabad, H. (1993) “ A bisensory testing procedure suitable for odorous irritants and emissions from building materials”. In: Proceedings of Indoor Air '93, Helsinki , International Conference on Indoor Air Quality and Climate, Vol. 1, pp. 107– 112. Bernhard, C., Kirchner, S., Knutti, R. and Lagoudi, A. (1995) “ Volatile organic compounds in 56 office buildings”. In: M. Maroni (ed.), Proceedings of Healthy Buildings '95, Milan , Vol. 3, pp. 1347– 1352. Bluyssen, P., Fernandes, de O., Groes, L., Clausen, G., Fanger, P.O., Valbørn, O., Bernhard, C. and Roulet, C. (1995) “ European audit study in 56 office buildings: conclusions and recommendations”. In: M. Maroni (ed.), Proceedings of Healthy Buildings '95, Milan , Vol. 3, pp. 1287– 1292. Bornehag, C.–G. (1994) MöUnsteranalys av Inomhusluft. UndersöUkning av Luftkvaliteten i Sjuka Hus med Flytspackelproblem, Stockholm , ByggforskningsråRdet (Thesis, R23: 1994) (in Swedish with English summary). Bornehag, C.–G. (1995) “ Pattern analysis of VOC in indoor air”. In: M. Maroni (ed.), Proceedings of Healthy Buildings '95, Milan , Vol. 1, pp. 487– 492. Brinke, J.T (1995) Development of New VOC Exposure Metrics and their Relationship to “Sick Building Syndrome” Symptoms, Berkeley , CA , Lawrence Berkeley Laboratory, University of California (Thesis, LBL-37652, UC-407). Broder, I., Corey, P. and Pilger, C. (1993) “ Influence of volatile organic compounds on the wellbeing of workers in office buildings”. In: P. Leslie and R. Perry (eds) Volatile Organic Compounds in the Environment, London , Indoor Air International, pp. 595– 604. Brown, S.K, Sim, M., Abramson, M. and Gray, C. (1994) “Concentrations of volatile organic compounds in indoor air – a review”, Indoor Air, 4, 123– 134. Burge, P. (1992) “The sick building syndrome – where are we in 1992?”, Indoor Environment, 1, 199– 203. Carrer, P., Cavallo, D., Fiocchi, V., Assini, R., Galli, L., Pierini, F., Troiano, P., Piccoli, B. and Maroni, M. (1995) “ Eye symptoms and signs in office workers: correlation with chemico-physical factors and VDU-work”. In: M. Maroni (ed.), Proceedings of Healthy Buildings '95, Milan , Vol. 3, pp. 1493– 1498. Chan, C.C, Lin, S.H and Her, G.R (1993) “Students' exposure to volatile organic compounds while commuting by motorcycle and bus in Taipei city”, Journal of the Air and Waste Management Association, 43, 1231– 1238. Chester, A. (1991) “Sick building syndrome and sinusitis”, The Lancet, 339 (letter and comment). Cometto-Muniz, E. and Cain, W. (1994) “Perception of odor and nasal pungency from homologous series of volatile organic compounds”, Indoor Air, 4, 140– 145. Cometto-Muniz, E. and Cain, W. (1995) “ Mixtures of volatile organic compounds: detection of odor, nasal pungency and eye irritation”. In: M. Maroni (ed.), Proceedings of Healthy Buildings '95, Milan , Vol. 1, pp. 171– 182. De Bortoli, M., Knöppel, H., Peil, A., Pecchio, E., Schlitt, H. and De Wilde, H. (1990) “ Investigation of the contribution of volatile organic compounds to air quality complaints in office buildings of the European parliament”. In: D.S Walkinshaw (ed.) Proceedings of Indoor Air '90, Ottawa , Canada Mortgage and Housing Corporation, Vol. 2, pp. 695– 700. Farant, J.–P., Baldwin, M., De Repentigny, F. and Robb, R. (1992) “Environmental conditions in a recently constructed office building before and after the implementation of energy conservation measures”, Applied and Occupational Environmental Hygiene, 7(2), pp. 93– 100. Fisk, W., Mendell, M., Daisey, J., Faulkner, D., Hodgson, A., Nemotollahi, M. and Macher, J. (1993) “Phase 1 of the California healthy building study: a summary”, Indoor Air, 3, 246– 254. Godish, T., Godish, D., Hooper, B. and Hooper, M. (1995) “ Latrobe valley indoor air quality study: health and house variables”. In: Proceedings of Indoor Air: an Integrated Approach, Amsterdam , Elsevier, pp. 211– 214. Gustafsson, H. (1992) Building Materials identified as Major Emission Sources: a Critical Review of Case Studies, Stockholm , Swedish Council for Building Research (D10). Gyntelberg, F., Suadicani, P., Nielsen, W.J, Skov, P., Valbjørn, O., Nielsen, P.A, Schneider, T., Jørgensen, O., Wolkoff, P., Wilkins, C.K, Gravesen, S. and Norn, S. (1994) “Dust and the sick building syndrome”, Indoor Air, 4, 223– 238. Haghighat, F, Donnini, G. and D'Addario, R. (1992) “Relationship between occupant discomfort as perceived and as measured objectively”, Indoor Environment, 1(2), 112– 118. Hammad, Y. (1994) “The problem of the ‘sick’ building: facts and implications: identifying and measuring indoor non-biological agents”, Journal of Allergy and Clinical Immunology, 94(2), Part 2, pp. 389– 393. Harving, H., Dahl, R. and Mølhave, L. (1991) “Lung function and broncial reactivity in asthmatics during exposure to volatile organic compounds”, American Review of Respiratory Diseases, 143, 751– 754. Hedge, A., Sterling, T.D, Sterling, E.M, Collett, C., Sterling, D.A and Nie, V. (1989) “Indoor air quality and health in two office buildings with different ventilation systems Environment International, 15, 115– 128. Henry, C., Fishbein, L., Meggs, W., Ashford, N., Schulte, P., Anderson, H., Osborne, S. and Sepkovic, D. (1991) “Approaches for assessing health risks from complex mixtures in indoor air: a panel overview”, Environmental Health Perspectives, 95, 135– 143. Hodgson, M. (1991) “Indoor air quality”, Allergy Proceedings, 12(6), pp. 371– 383. Hodgson, M., Frohliger, J., Permar, E., Tidwell, C., Traven, N., Olenchock, S. and Karpf, M. (1991) “Symptoms and microenvironmental measures in nonproblem buildings”, Journal of Occupational Medicine, 33(4), pp. 527– 533. Hodgson, M. (1992) “Field studies on the sick building syndrome”, Annals of the New York Academy of Sciences, 641, 21– 36. Hodgson, M., Muldoon, S., Collopy, P. and Olesen, B. (1992) “ Sick building syndrome symptoms, work stress and environmental measures”. In: Proceedings of IAQ '92: Environment for People, Atlanta , GA , American Society of Heating, Refrigerating and Air-Conditioning Engineers, pp. 47– 56. Hodgson, M., Levin, H. and Wolkoff, P. (1994) “Volatile organic compounds and indoor air”, Journal of Allergy and Clinical Immunology, 94(2), Part 2, pp. 296– 303. Hudnell, K., Otto, D., House, D. and Mølhave, L. (1990) Odor and Irritation Effects of a VOC Mixture, Research Triangle Park, NC, US Department of Commerce, National Technical Information Service (Report PB90-263310). Hudnell, K., Otto, D., House, D. and Mølhave, L. (1992) “Exposure of humans to a volatile organic mixture, II. Sensory”, Archives of Environmental Health, 47(1), 31– 38. Hudnell, K., Otto, D. and House, D. (1993) “ Time course of odor and irritation effects in humans exposed to a mixture of 22 volatile organic compounds”. In: Proceedings of Indoor Air '93, Helsinki , International Conference on Indoor Air Quality and Climate, Vol. 1, pp. 567– 572. Iregren, A., Löf, A., Toomingas, A. and Wang, Z. (1993) “Irritation effects from experimental exposure to n-Butyl Acetate”, American Journal of Industrial Medicine, 24, 727– 742. Johnsen, C., Heinig, J., Schmidt, K., Albrechtsen, O., Nielsen, P., Wolkoff, P., Nielsen, G., Hansen, L. and Franck, C. (1991) “A study of human reactions to emissions from building materials in climate chambers, Part I: Clinical data performance and comfort, Indoor Air, 4, 377– 388. Karpe, P., Kirchner, S. and Rouxel, P. (1995) “ Sensory evaluation of wall and floor coverings using an odour intensity method”. In: M. Maroni (ed.), Proceedings of Healthy Buildings '95, Milan , Vol. 2, pp. 935– 940. Kærgaard, S., Mølhave, L. and Pedersen, O. (1989) “Human reactions to indoor air pollutants n-decane”, Environment International, 15, 473– 482. Kjærgaard, S., Mølhave, L. and Pedersen, O. (1991) “Human reactions to a mixture of indoor air volatile organic compounds”, Atmospheric Environment, 25A(8), 1417– 1426. Kjærgaard, S., Rasmussen, T., Mølhave, L. and Pedersen, O. (1995) “An experimental comparison of indoor air VOC effects on hayfever- and healthy subjects”. In: Proceedings of Healthy Buildings '95, Vol. I, pp. 567– 572. Koren, H., Graham, D. and Devlin, R. (1992a) “Exposure of humans to a volatile organic mixture. III. Inflammatory response”, Archives of Environmental Health, 47(1), pp. 39– 44. Koren, H. and Devlin, R. (1992b) “Human upper respiratory tract responses to inhaled pollutants with emphasis on nasal lavage”, Annals of the New York Academy of Sciences, Vol. 641, 215– 223. Kosiainen, R. (1995) “Volatile organic compounds in the indoor air of normal and sick houses”, Atmospheric Environment, 29(6), 693– 702. Krzyzanowski, M., Quackenboss, J. and Lebowitz, M. (1990) “Chronic respiratory effects of indoor formaldehyde exposure”, Environmental Research, 52, 117– 125. Liao, S., Bacon-Shone, J. and Kim, Y.–S. (1991) “Factors influencing indoor air quality in Hong Kong: measurements in offices and shops”, Environmental Technology, 12, 737– 745. Lin, J. and Yao, Y.–H. (1993) “Formaldehyde in conventional homes in Taiwan”, Environment International 19, 561– 568. Llewellyn, J. and Smith, L. (1995) “ Indoor air quality in the UK: the Avon longitudinal study of pregnancy and childhood (Alspac)”. In: M. Maroni (ed.), Proceedings of Healthy Buildings '95, Milan , Vol. 1, pp. 373– 378. Lundin, L. (1993) “ Symptom patterns and air quality in a sick library”. In: Proceedings of Indoor Air '93, Helsinki , International Conference on Indoor Air Quality and Climate, Vol. 1, pp. 127– 132. Meggs, W. (1993) “Neurogenic inflammation and sensitivity to environmental chemicals”, Environmental Health Perspectives, 101(3), pages 234– 238. Menzies, R., Tamblyn, R., Farant, J.P, Hanley, J., Tamblyn, R.T, Nunes, F. and Marcotte, P. (1991) “ The effect of varying levels of outdoor ventilation on symptoms of the sick building syndrome”. In: Proceedings of IAQ '91: Healthy Buildings, Atlanta , GA , American Society of Heating, Ventilating and Air-Conditioning Engineers, pp. 90– 96. Menzies, R., Tamblyn, R.T, Hanley, J., Nunes, F. and Tamblyn, R.M (1993) “ Impact of exposure to multiple contaminants on symptoms of the sick building syndrome”. In: Proceedings of Indoor Air '93, Helsinki , International Conference on Indoor Air Quality and Climate, Vol. 1, pp. 363– 368. Merchan, M.L and de la Serna, J. (1986) “Formaldehyde as an indoor pollutant”, Toxicological and Environmental Chemistry, 13, 17– 25. Montgomery, D. and Kalman, A. (1989) “Indoor/outdoor air quality: reference pollutant concentrations in complaint-free residences”, Applied Industrial Hygiene, 4(1), pp. 17– 20. Moschandreas, D., Relwani, S. and Novesel, D. (1990) “ Characterization of a healthy building”. In: D.S Walkinshaw (ed.), Proceedings of Indoor Air '90, Ottawa , Canada Mortgage and Housing Corporation, Vol. 1, pp. 555– 560. Mølhave, L. (1982) “Indoor air pollution due to organic gases and vapors of solvents in building materials”, Environment International, 8, 117– 127. Mølhave, L., Bach, B. and Pederson, O. (1986) “Human reactions to low concentrations of volatile organic compounds”, Environment International, 12, 167– 175. Mølhave, L. (1989) “The sick buildings and other buildings with indoor climate problems”, Environment International, 15, 65– 74. Mølhave, L. (1990) “ Volatile organic compounds, indoor air quality and health”. In: D.S Walkinshaw (ed.) Proceedings of Indoor Air '90, Ottawa , Canada Mortgage and Housing Corporation, Vol. 1, pp. 15– 33. Mølhave, L. (1991) “Indoor climate, air pollution and human comfort”, Journal of Exposure Analysis and Environmental Epidemiology, 1(1), pp. 63– 81. Mølhave, L., Jensen, J. and Larsen, S. (1991) “Subjective reactions to volatile organic compounds as air pollutants”, Atmospheric Environment, 25A(7), 1238– 1293. Mølhave, L., Liu, Z., Jørgensen, A., Pederson, O. and Kjærgaard, S. (1993a) “Sensory and physiological effects on humans of combined exposures to air temperature and volatile organic compounds”, Indoor Air, 3, 155– 169. Mølhave, L., Kjærgaard, S., Pedersen, O., Jørgensen, A. and Pedersen, T. (1993b) “ Human response to different mixtures of volatile organic compounds”. In: Proceedings of Indoor Air '93, Helsinki , International Conference on Indoor Air Quality and Climate, Vol. 1, pp. 555– 560. Mølhave, L., Dueholm, S. and Jensen, L. (1995) “Assessment of exposures and health risks related to formaldehyde emissions from furniture: a case study”, Indoor Air, 5, 104– 119. Nelson, C, Clayton, C, Wallace, L., Highsmith, V, Kollander, M., Bascom, R. and Leaderer, B. (1991) “ EPA's indoor air quality and work environment survey: relationships of employees' self-reported health symptoms with direct indoor air quality measurements”. In: Proceedings of IAQ '91: Healthy Buildings, Atlanta , GA , American Society of Heating, Refrigerating and Air-Conditioning Engineers, pp. 22– 32. Nelson, N., Kaufman, J., Burt, J. and Karr, C. (1995) “Health symptoms and the work environment in four non-problem United States office buildings”, Scandinavian Journal of Work, Environment and Health, 21, 51– 59. Nexø, B. (1995) “Risk assessment methodologies for carcinogenic compounds in indoor air”, Scandinavian Journal of Work, Environment and Health, 21, 376– 381. Noma, E., Berglund, B., Berglund, U., Johansson, I. and Baird, J. (1988) “Joint representation of physical locations and volatile organic compounds in indoor air from a healthy and a sick building”, Atmospheric Environment, 22(3), 451– 460. Norbäck, D., Rand, G., Michel, I. and Amcoff, S. (1989) “The prevalence of symptoms associated with sick buildings and polluted industrial environments as compared to unex-posed reference groups without expressed dissatisfaction”, Environment International, 15(1-6), 85– 94. Norbäck, D., Michel, I. and Widström, J. (1990a) “Indoor air quality and personal factors related to the sick building syndrome”, Scandinavian Journal of Work, Environment and Health, 16, 121– 128. Norbäck, D., Torgén, M. and Edling, C. (1990b) “Volatile organic compounds, respirable dust and personal factors related to prevalence and incidence of the sick building syndrome in primary schools”, British Journal of Industrial Medicine, 47, 733– 741. Norbäck, D. and Edling, C. (1991) “Environmental, occupational and personal factors related to the prevalence of the sick building syndrome in the general population”, British Journal of Industrial Medicine, 48, 451– 462. Norbäck, D., Edling, C., Wieslander, G. and Ramadhan, S. (1993) “ Exposure to volatile organic compounds (VOC) in the general Swedish population and its relation to perceived air quality and the sick building syndrome (SBS)”. In: Proceedings of Indoor Air '93, Helsinki , International Conference on Indoor Air Quality and Climate, Vol. 1, pp. 573– 578. Norbäck, D., Wieslander, G., Ström, G. and Edling, C. (1994) “Exposure to volatile organic compounds of microbial origin (MVOC) during indoor application of water-based paints”, Indoor Air, 5, 166– 170. Norbäck, D. (1995) “Subjective indoor air quality in schools the influence of high room temperature, carpeting, fleecy wall materials and volatile organic compounds”, Indoor Air, 5, 237– 246. Norbäck, D., Björnsson, E., Janson, C., Widström, J. and Boman, G. (1995a) “Asthmatic symptoms and volatile organic compounds: formaldehyde and carbon dioxide in dwellings”, Occupational and Environmental Medicine, 52, 388– 395. Norbäck, D., Björnsson, E., Janson, C. and Boman, G. (1995b) “ Sick building syndrome (SBS) and the home environment – the role of inflammatory reactions and exposure to volatile organic compounds”. In: J. J. Knight and R. Perry (eds) Second International Conference. Volatile Organic Compounds in the Environment, London , Indoor Air International, pp. 179– 185. Nordsträm, K., Norbäck, D. and Akselsson, R. (1994) “Effect of air humidification on the sick building syndrome and perceived indoor air quality in hospitals: a four-month longitudinal study”, Occupational and Environmental Medicine, 51, 683– 688. Nordsträm, K., Norbäck, D. and Akselsson, R. (1995) “Influence of indoor air quality and personal factors on the sick building syndrome in Swedish geriatric hospitals”, Occupational and Environmental Medicine, 52, 170– 176. Otto, D., Mølhave, L., Rose, G., Hudnell, K. and House, D. (1990a) “Neurobehavioral and sensory irritant effects of controlled exposure to a complex mixture of volatile organic compounds”, Neurotoxicology and Teratology, 12, 649– 652. Otto, D., Mølhave, L., Goldstein, G., O'Neill, J., House, D., Rose, G., Berntsen, J., Counts, W., Fowler, S., Hudnell, K. and Meade, S. (1990b) Neurotic Effects of Controlled Exposure to a Complex Mixture of Volatile Organic Compounds, Research Triangle Park, NC, US Department of Commerce, National Technical Information Service (Report PB90-186438). Otto, D., Hudnell, K. and House, D. (1992) “Exposure of humans to a volatile organic mixture. I. Behavioral assessment”, Archives of Environmental Health, 47(1), pp. 23– 30. Otto, D., Hudnell, K., House, D. and Prah, J. (1993) “ Neurobehavioral and subjective reactions of young men and women to a complex mixture of volatile organic compounds”. In: Proceedings of Indoor Air '93, Helsinki , International Conference on Indoor Air Quality and Climate, Vol. 1, pp. 59– 64. Prah, J., Hazucha, M., Horstman, D., Garlington, R., Case, M., Ashley, D. and Tepper, J. (1993) “ Pulmonary, respiratory and irritant effects of exposure to a mixture of VOCs at three concentrations in young men”. In: Proceedings of Indoor Air '93, Helsinki , International Conference on Indoor Air Quality and Climate, Vol. 1, pp. 607– 612. Quackenboss, J., Lebowitz, M., Michaud, J. and Bronnimann, D. (1989) “Formaldehyde exposure and acute health effects study”, Environment International, 15, 169– 176. Rothweiler, H., Wäger, A. and Schlatter, C. (1992) “Volatile organic compounds and some very volatile organic compounds in new and recently renovated buildings in Switzerland”, Atmospheric Environment, 26A(12), 2219– 2225. Rothweiler, H. and Schlatter, C. (1993) “Human exposure to volatile organic compounds in indoor air – a health risk?”, Toxicological and Environmental Chemistry, 40, 93– 102. Rudnai, P., Sarkany, E., Banhidi, L., Gereben, Z., Bacskai, J., Kertesz, M., Martini, E and Selmeczy, K. (1994) “ Importance of human and housing factors in the prevalence of SBS symptoms among inhabitants of a residential area in Budapest”. In: Proceedings of Healthy Buildings '94, Budapest , Vol. 1, pp. 487– 492. Rylander, R., Persson, K., Goto, H., Yuasa, K. and Tanaka, S. (1992) “Airborne Beta-l,3-Glucan may be related to symptoms in sick buildings”, Indoor Environment, 1, 263– 267. Samet, J. and Lambert, W. (1991) “Epidemiological approaches for assessing health risks from complex mixtures in indoor air”, Environmental Health Perspectives, 95, 71– 74. Seifert, B. (1990) “ Regulating indoor air”. In: D.S Walkinshaw (ed.) Proceedings of Indoor Air '90, Ottawa , Canada Mortgage and Housing Corporation, Vol. 5, pp. 35– 49. Skov, P., Valbjørn, O. and DISG (1987) “The sick building syndrome in the office environment: the Danish town hall study”, Environment International, 13, pp. 339– 349. Skov, P., Valbjørn, O. and Pedersen, B. (1990) “Influence of indoor climate on the sick building syndrome in an office environment”, Scandinavian Journal of Work, Environment and Health, 16, 363– 371. Stridh, G., Fredriksson, R., Jansson, L., Robertson, S. and Viklund, L. (1993) “ Levels of volatile compounds (VOC) and formaldehyde in the Swedish housing stock”. In: Proceedings of Indoor Air '93, Helsinki , International Conference on Indoor Air Quality and Climate, Vol. 2, pp. 159– 163. Stridh, G. and Andersson, K. (1995) “ The effect of different restoring measures in a domestic area with severe indoor climate problems”. In: Proceedings of Indoor Air: An Integrated Approach, Amsterdam , Elsevier, pp. 247– 250. Ström, G., West, J., Wessén, B. and Palmgren, U. (1994) “Quantitative analysis of microbial volatiles in damp Swedish houses”. In: Air Quality Monographs, Vol. 2, Health Implications of Fungi in Indoor Environments, pp. 291– 305. Suh, H., Koutrakis, P. and Spengler, J. (1994) “The relationship between airborne acidity and ammonia in indoor environments”, Journal of Exposure Analysis and Environmental Epidemiology, 4(1), pp. 1– 22. Sundell, J., Andersson, B., Andersson, K. and Lindvall, T. (1993) “Volatile organic compounds in ventilating air in buildings at different sampling points in the buildings and their relationship with the prevalence of occupant symptoms”, Indoor Air, 3, 82– 93. Sundell, J. and Kjellman, M. (1994) “Luften vi andas inomhus. Inornhusmiljöens betydelse för allergi och annan överkänslighed”, Folkhälsoinstitutet, 16. Sverdrup, C., Andersson, K. and Andersson, S. (1990) “ A comparative study of indoor climate and human health in 74 day care centers in Malmo, Sweden”. In: D.S Walkinshaw (ed.) Proceedings of Indoor Air '90, Ottawa , Canada Mortgage and Housing Corporation, Vol. 2, pp. 651– 655. Hrasher, J., Madison, R., Broughton, A. and Gard, Z. (1989) “Building-related illness and antibodies to albumin conjugates for formaldehyde, toluene deisocyanate and trimellitic anhydride”, American Journal of Industrial Medicine, 15, 187– 195. Utell, M.J and Looney, R.J (1995) “Environmentally induced asthma”, Toxicology Letters, 82/83, 47– 53. Wallace, L., Pellizzari, E. and Wendel, C. (1990) Total Volatile Organic Compounds Concentrations in 2700 Personal, Indoor, and Outdoor Air Samples Collected in the US EPA TEAM Studies, Research Triangle Park, US Department of Commerce, National Technical Information Service (Report PB91-182857). Wallace, L. (1991) “Comparison of risks from outdoor and indoor exposure to toxic chemicals”, Environmental Health Perspectives, 95, 7– 13. Wallace, L., Nelson, W. and Ziegenfus, R. (1991) “The Los Angeles Team study: personal exposures, indoor-outdoor air concentrations, and breath concentrations of 25 volatile organic compounds”, Journal of Exposure Analysis and Environmental Epidemiology, 1(2), pp. 157– 167. Ware, J., Spengler, J., Neas, L., Samet, J., Wagner, G., Coultas, D., Ozkaynak, H. and Schwab, M. (1993) “Respiratory and irritant health effects of ambient volatile organic compounds – the Kanawha county study”, American Journal of Epidemiology, 137(12), pp. 1287– 1301. Weschler, C., Shields, H. and Rainer, D. (1990) “Concentrations of volatile organic compounds at a building with health and comfort complaints”, Journal of the American Industrial Hygiene Association, 51, pp. 261– 268. Wessén, B., Ström, G. and Schoeps, K. (1995) “ MVOC-pro-files – a tool for indoor air quality assessment. Proceedings of Indoor Air: an Integrated Approach, Amsterdam , Elsevier, pp. 67– 70. Wieslander, G., Norbäck, D., Björnsson, E., Janson, C. and Boman, G. (1995) “ Asthma and blood eosinophils in relation to exposure to fresh painted indoor surfaces and volatile organic compounds (VOC)”. In: G. Flatheim, K. Berg, K. I. Edvardsen (eds) Proceedings of Indoor Air Quality in Practice, Oslo , pp. 346– 352. Wilkins, C.K, Wolkoff, P., Gyntelberg, F., Skov, P. and Valbjørn, O. (1993) “Characterization of office dust by VOCs and TVOC release – identification of potential irritant VOCs by partial least squares analysis”, Indoor Air, 3, 283– 290. Willers, S., Andersson, S., Andersson, R., Granten, J., Sverdrup, C. and Rosell, L. (1995) “ Air concentrations of total organic compounds (TVOC) and carbon dioxide (CO2) and sick building syndrome (SBS) – symptoms among the staff in schools and kindergartens”. In: J.J Knight and R. Perry (eds), Second International Conference. Volatile Organic Compounds in the Environment, London , Indoor Air International, pp. 187– 192. Wolkoff, P., Nielsen, G., Hansen, L., Albrechtsen, O., Johnsen, C., Heinig, J., Franck, C. and Nielsen, P. (1991) “A study of human reactions to building materials in climate chambers. Part II, VOC measurement, mouse bioassay and decipol evaluation in the 1-2 mg/m3 TVOC range”, Indoor Air, 1(4), 389– 403. Wolkoff, P., Johnsen, C., Franck, C., Wilhardt, P. and Albrechtsen, O. (1992) “A study of human reactions to office machines in a climate chamber”, Journal of Exposure Analysis and Environmental Epidemiology, Suppl. 1. Wolkoff, P. (1995) Volatile Organic Compounds – Sources, Measurements, Emissions, and the Impact on Indoor Air Quality, Copenhagen , Arbejdstilsynet, National Institute of Occupational Health. Wolkoff, P. and Nielsen, P. (1996) “A new approach for indoor climate labeling of building materials-emission testing, modeling, and comfort evaluation”, Atmospheric Environment, 30(15), 2679– 2689. World Health Organization (1989) Indoor Air Quality: Organic Pollutants, Copenhagen , WHO Regional Office for Europe (EURO Reports and Studies No. 111). Zhang, J., Wilson, W. and Lioy, P. (1994) “Sources of organic acids in indoor air: a field study”, Journal of Exposure Analysis and Environmental Epidemiology, 4(1), pp. 25– 47. Zweers, T., Skov, P., Valbjørn, O. and Mølhave, L. (1990) “The effect of ventilation and air pollution on perceived indoor air quality in five town halls”, Energy and Buildings, 14, 175– 181. Citing Literature Volume7, Issue2June 1997Pages 78-91 ReferencesRelatedInformation