Turbulent convection experiment to support ivr strategy

MA Li,LI Jing,JI Shui,CHANG Huajian
2015-01-01
Abstract:This paper is mainly to research the metal layer heat transfer through studying the correlations of the heat transfers. The Globe-Dropkin (G-D) [1] correlation (1.5•10<Ra<6.8•10) and Chu-Churchill (C-C) [2] correlation have been widely used to calculate the heat flux in the metal layer. However, with the increase of reactor power, both the Ra and the rate of heat transfer below the bottom of metal layer of the molten pool will increase, and in this case the Ra even can reach 10 to 10 for the high power reactor. Accordingly, the application scope of G-D correlation is not suitable for the high power reactor. Meanwhile, there is an ongoing debate about the correct correlation in the field. Therefore, the experiment purpose is to test and validate the G-D correlation at high Ra of the metal layer (10<Ra<10) with the Heat transfer behavior of mEtal Layer experiMent (HELM) facility. If the experiment results can’t fit well with the G-D correlation, an appropriate correlation should be set up at high Ra for the high power reactor which can predict the heat flow distribution using experiment I result and C-C correlation in metal layer. The experiments are divided into two parts. Each part concerns 39 runs and 47 runs experimental conditions respectively. Its corresponding results are obtained that the Nusselt number is found to be proportional to Ram in the range 3.93•10<Ra<3.57•10 at middle Prandtl number (Pr=7 for water). Furthermore, the experiment results can predict the relationship between axial and radial heat transfer well.
What problem does this paper attempt to address?