MEASUREMENT AND ANALYSIS OF SYNCHROTRON TUNE VARIATION WITH BEAM CURRENT IN BEPCII *

Na Wang,Z. H. Duan,Gang Xu,Haisheng Xu,Chenghui Yu,Yuan Zhang
DOI: https://doi.org/10.18429/jacow-ipac2018-thpak016
2018-01-01
Abstract:Coherent synchrotron frequency shift is observed during machine studies in BEPCII (Beijing Electron Positron Collider Upgrade). The results show that the synchrotron frequency varies parabolicly with the increase of the beam current. This phenomenon is supposed to be induced by the interaction of the beam with the fundamental mode of the accelerating cavity. In order to explain this phenomenon, a simple physical model is developed from the couple bunch instability theory. The analytical estimations based on the physical model show good agreement with the measurements. INTRODUCTION BEPCII is an electron positron collider with a design luminosity of 11033 cm-2s-1 at beam energy of 1.89 GeV [1]. To achieve high luminosity, multi-bunch collision with double ring is applied. Electron and positron beam circulate in separate storage rings, while colliding at the common interaction point. The beam instability issues are important topics for high beam performance. Superconducting RF cavity of 499.8 MHz is used for its advantage of high accelerating gradient and well-damped HOMs. During the machine studies, quadratic growth of synchrotron tune versus beam current were observed in both electron and positron rings. The main parameters of BEPCII relevant to the machine studies are listed in Table 1, where BER represents the electron storage ring and BPR represents the positron storage ring. In this paper, measurements of frequency shift for the lowest synchrotron sideband with beam current in BER and BPR are first introduced. The phenomena are then explained by the coupled bunch instability model with the fundamental RF resonator. A simplified physical model is developed to explain the experiments. MEASUREMENTS ON THE SYNCHROTRON FREQEUNCY TUNE SHIFT During the operation of BEPCII, some current dependent phenomena were observed. Measurements of the frequency shift for the lowest synchrotron sideband with beam current was recently performed in BER and BPR. During the measurements, each beam consists of 120 bunches with bunch spacing of 6 ns. Figures 1 and 2 show the measured synchrotron oscillation frequency as a function of total beam current in BER and BPR, respectively. The dots represent the measured data, and the solid lines are the parabolic fits of the data. The fitting curves show excellent agreement with the measured data. The parabolic increase of the synchrotron frequency with beam current is supposed to be induced by the fundamental mode of the RF cavity, whose resonant frequency is often tuned along with the variation of the beam current. More details will be given in the following sections. Table 1: Main Parameters Relevant to the Machine Studies Parameters, Unit BER BPR Beam energy E, GeV 1.89 Circumference C, m 237.53 Revolution freq. f0, MHz 1.2621 Harmonic number h 396 RF frequency frf, MHz 499.8 Bunch number nb 120 Momentum compaction p 0.0171 0.170 Synchrotron freq. fs0, kHz 37.959 36.823 RF voltage Vc, MV 1.52 1.52 R/Q of the RF cavity,  47.65 47.65 Q of the RF cavity 5.4108 9.6108 Figure 1: Variation of the synchrotron oscillation tune with beam current for BER (“”: measurement data, solid line: fitting curve). ___________________________________________ † email address: wangn@ihep.ac.cn 9th International Particle Accelerator Conference IPAC2018, Vancouver, BC, Canada JACoW Publishing ISBN: 978-3-95450-184-7 doi:10.18429/JACoW-IPAC2018-THPAK016 05 Beam Dynamics and EM Fields D06 Coherent and Incoherent Instabilities Measurements and Countermeasures THPAK016 3237 Co nt en tf ro m th is w or k m ay be us ed un de rt he te rm so ft he CC BY 3. 0 lic en ce (© 20 18 ). A ny di str ib ut io n of th is w or k m us tm ai nt ai n at tri bu tio n to th e au th or (s ), tit le of th e w or k, pu bl ish er ,a nd D O I.
What problem does this paper attempt to address?