A Comparison of LVDT and RC Methods to Characterize the Performance of a Linear Compressor

L. Y. Wang,D. L. Liu,J. K. Zhu,Z. H. Gan,L. M. Qiu,Y. N. Wu
2012-01-01
Abstract:A recently employed approach for characterizing the PV power of a linear compressor using a resistive-capacitive (RC) type acoustic circuit is compared to the more conventional approach that utilizes linear variable displacement transducers (LVDT) mounted on the compressor pistons. Experiments using the two methods have been carried out and results show that both approaches agree well with calculations of the PV power at the piston face. In terms of absolute numbers, the PV power at the compressor outlet (that is the inlet of a regenerator) obtained by the RC approach is 5%~20% lower than the PV power on piston face obtained by the LVDT method. The RC load approach provides advantages such as simple assembly, non-contact, and the ability to simulate the impedance conditions of cold heads. In addition, it may provide a new method to investigate linear compressors losses.
What problem does this paper attempt to address?