INTRODUCTION OF THE LASER INTENSITY MEASUREMENT SYSTEM FOR THE FELiChEM *

FeiLiang Gao,Letian Huang,Ping Lu,Biao Sun,Jigang Wang,Fangfang Wu,Yongliang Yang,Tianyu Zhou
DOI: https://doi.org/10.18429/jacow-ipac2018-thpml115
2018-01-01
Abstract:The FELiChEM is a new infrared free electron laser (IR-FEL) facility, which is being built in the National Synchrotron Radiation Laboratory (NSRL) in Heifei, China. The facility will provide continuously tunable pulsed laser radiation covering the mid-infrared (MIR) wavelength range from 2.5 to 50μm and the far-infrared (FIR) range from 40 to 200μm. The output macro pulsed laser width is 5-10μs and pulsed laser power is 2-10kW. In order to evaluate pulsed laser saturation time and FEL optical cavity losses, the rise time and fall time of macro pulsed laser need to be measured. Laser intensity measurement system for the FELiChEM is being designed. This system is composed of optical system, pyroelectric detector and electronics. Each module will be described in detail in this paper. The laser intensity measurement system was tested under offline and online conditions. The results showed that pulsed laser of 10μs width can be measured and the design requirement can be met with this system. INTRODUCTION FELiChEM is a new experimental facility that can generate mid-infrared and far-infrared laser. The laser parameters for the FELiChEM are shown in Table 1 [1]. According to these parameters, the calculated power of the macro-pulse and average power are 2-10kW and 2W respectively. In order to evaluate pulsed laser saturation time and FEL optical cavity losses, a laser intensity measurement system is being designed to evaluate the laser parameters and speed up the machine commissioning for the FELiChEM facility. Table 1: The Laser Parameters of the FELiChEM Parameter Specification Spectral range 2.5-50μm (MIR) 40-200μm (FIR) Bandwidth 0.3%-3% Macro-pulse energy 10-100mJ Macro-pulse length 5-10μs Repetition of macropulse 20Hz Micro-pulse energy 5-100μJ Micro-pulse length 1-5ps THE LASER INTENSITY MEASUREMENT SYSTEM The layout of the laser intensity measurement system for the FELiChEM facility is shown in the Fig. 1. The infrared pulse laser coupled out from the optical cavity reaches the laser intensity measurement system through a nitrogen-filled pipe, which can reduce the absorption of the infrared laser by the air. MIR attenuator & FIR attenuator Pyroelectric detector & Electronics Spricon Pyrocam V Oscilloscope PC Stepping motor Off-axis parabolic mirror Figure 1: Layout of the laser intensity measurement system. Due to the high average power of the macro-pulse of the FEL, the laser needs to be attenuated by the attenuator to protect the detector. Then laser is focused by an offaxis parabolic mirror and absorbed by the detector. Since laser profile also need to be monitored, an infrared camera named Spricon Pyrocam V was also placed on the optical platform. The off-axis parabolic mirror will be controlled by a stepping motor to transfer the FEL laser to the pyroelectric detector or the pyroelectric camera. As the topic of this paper is to introduce the laser intensity measurement system, so laser profile measurement will not be introduced. The main composition for this system will be presented in the following. Pyroelectric Detector and Electronics Pyroelectric detector is a detector that converts radiation pulsed light into electrical signal by the pyroelectric effect [2]. Compared to cryogenic detectors, the pyroelectric detector can work at the room temperature and a wider response range. It has a lower cost, but a lower detectivity and responsibility. The output signal for the pyroelectric detector is proportional to the temperature characteristics of the pyroelectric material and the area of the detector. The pyroelectric detector used in the laser intensity measurement system is ___________________________________________ *Supported by the National Science Foundation of China (Grant No. 11705203, 11575181, 11605202), Chinese Universities Scientific Fund (Grant No. WK2310000057) and the National Key Research and Development Program of China (No. 2016YFA0402000) † ylyang@ustc.edu.cn ‡ bgsun@ustc.edu.cn 9th International Particle Accelerator Conference IPAC2018, Vancouver, BC, Canada JACoW Publishing ISBN: 978-3-95450-184-7 doi:10.18429/JACoW-IPAC2018-THPML115
What problem does this paper attempt to address?