A comparative study on Fabry-Perot interferometer and iodine vapor filter for direct-detection Doppler wind measurements with a Cabanne-Mie lidar

Jia Yue,Chiao-Yao She,John W. Hair,Jin-Jia Guo,Song-Hua Wu,Zhao-Ai Yan,Zhi-Shen Liu
2006-01-01
Abstract:Two techniques for frequency analysis are currently employed by different research groups utilizing directdetection methods for lidar Doppler wind measurements, the double-edge Fabry-Perot interferometer (FPI) and the iodine vapor filter (IVF). The performances of four methods at various frequencies: (a) a double-edge FPI at 1064 nm (ir-FPI), (b) a double-edge FPI at 355 nm (uv-FPI), (c) a singleedge IVF at 532 nm (se-IVF), (d) a double-edge IVF at 532 nm (de-IVF) are analyzed. How the aerosol mixing ratio Rb, affects the instrument sensitivity, signal-tonoise ratio (S/N) and thus wind measurement uncertainty is discussed. Both uv-FPI and ir-FPI have to be utilized to cover different altitude and various aerosol conditions. On the other hand, the IVF system is able to operate consistently for different atmospheric regions. However, the uncertainty in Rb can cause serious errors in wind measurements for IVF systems, thus we discuss not only the means to incorporate a credible determination of Rb, but also its associated S/N degradation in analysis.
What problem does this paper attempt to address?