Study on energy modeling methods of atrium buildings
Yiqun Pan,Yuming Li,Zhizhong Huang
2009-01-01
Abstract:In recent years, highly glazed atriums are favorable to architectural aesthetics and to taking advantage of daylighting and solar heating. However, the estimation of the building load of an atrium building is difficult because of the complex thermal phenomena occurred in the atrium space. The study aims to find out the methods of conducting accurate simulations of the cooling loads of various types of atriums, using whole building energy simulation tool – EnergyPlus. Cases of atrium buildings are collected and classified into various categories. For every category of atrium building, CFD models and energy models are developed. The simplified methods of simulating the cooling loads of atriums using different room air temperature patterns are summarised and applied to EnergyPlus. The non-dimensional height room air models with CFD results are defined as the baseline models to find out the most accurate model for every category of atrium building. In order to validate the methods an actual atrium office building is tested on site on a typical summer day and the results are compared with simulation results using the simplified methods. Finally, appropriate methods of simulating different types of atrium buildings are proposed. INTRODUCTION With the development of economy and technology, more new skyscrapers are built and even higher than the existing ones around the world. High-glazed atrium-type spaces are popularly employed in these high rise buildings, due to its architectural aesthetics as well as daylighting and solar heating advantages. Because of the complex thermal-airflow-coupled phenomena normally occurred in atrium spaces, conventional load calculation and system design procedures that relying on the assumption that zone air is thoroughly mixed –“well-stirred” zone model – might be inadequate to predict the thermal behaviour and to achieve good indoor environment and energy performance in these spaces (B. Griffith, Q. Chen 2004). The well-stirred zone model is well applied to typical forced air system where relatively good air mixing is the design intent, but might cause unacceptable calculation errors for such system designs or operating modes as displacement ventilation, underfloor air distribution, chilled ceiling, natural ventilation, mix-mode ventilation, large spaces e.g., atria, auditoria, and so on, where nonuniformity of zone air temperature is designed intently to improve energy efficiency and indoor air quality. It is of importance to consider the impact of nonuniform indoor air temperature on building load and energy use, which create a need for a different load calculation and system design method. Several researchers made efforts to find out a relatively accurate method for these particular spaces and systems. Griffith and Chen (2004) developed a framework and computer code for coupling detailed air models with building energy and load calculations and the heat balance model is reformulated to use zone air temperature as a variable defined separately for each surface, which can be applied for the energy modelling of spaces where the room air is stratified. Beausoleil-Morrison (2001) developed an adaptive controller to manage the interactions between the thermal and CFD modelling domains and implemented it within the ESP-r simulation program to support the conflation of CFD with dynamic whole building thermal simulation. Zhai et al (2001) described several different approaches to integrating energy simulation and CFD and proposed a staged coupling strategy for different programs. Djunaedy et al (2005) studied the implementation of external coupling between building energy simulation and CFD rather than a traditional internal coupling between the two different domains. The particularity of the energy performance of the high-glazed large atrium due to its large size and Eleventh International IBPSA Conference Glasgow, Scotland July 27-30, 2009