Multi-Parameters Influence Analysis of Overall Cooling Effectiveness

Ming-Fei LI,Xue-Ying LI,Jing REN,Hong-De JIANG
2017-01-01
Abstract:Advanced turbine cooling technologies become more complex and diversified.The performance of cooling system is the result of various cooling components.The article built a onedimensional conjugate heat transfer model which is based on coolant heat pick-up coefficient and heat transfer ratio.The model was verified by the experiment results.Multi-parameters influence mechanism was researched by the model.The results show that a good agreement can be found between the model prediction and experiment results.The reliability of the one-dimensional analysis method could be verified.Heat transfer ratio,film cooling effectiveness and Biot number of TBC have positive correlation to overall cooling effectiveness,while heat pick-up coefficient and Biot number of metal are parameters negative with overall effectiveness.TBC would reduce the sensitivity of internal cooling and film cooling both.Further quantified and sensitivity results can be concluded by the isograms analysis.
What problem does this paper attempt to address?