Electrical Capacitance Tomography System Design Based on Industrial Bus Standard

XU Kang,TAN Chao,WU Hao,DONG Feng
DOI: https://doi.org/10.13700/j.bh.1001-5965.2017.0049
2017-01-01
Abstract:To ensure that the electrical capacitance tomography (ECT)system meets the requirements of multiphase flow parameter measurement in aerospace field,an ECT system based on the CPCI industrial bus standard is designed. A high-performance field-programmable gate array (FPGA)chip is used as the main control chip to realize the integrated design of signal excitation module,multiplex switch module,data process-ing module,data demodulation and transmission module. The signal is preprocessed with signal filtering,am-plification and phase-sensitive demodulation,and then the demodulated capacitance data is transferred to the host computer through the CPCI industrial bus interface. Finally,the image is reconstructed in the host com-puter. The experimental results of ECT system show that the image acquisition speed can reach 1785 frames per second at 1 MHz excitation signal with 8 electrode sensor and 10-cycle test signal for demodulation. The system can operate under a SNR of above 60 dB,while the imaging results have good spatial resolution.
What problem does this paper attempt to address?