Cortical Bone Fracture Imaging Using Velocity Model Based Multistatic Synthetic Aperture Ultrasound

Yunqing Li,Kailiang Xu,Chen Jiang,Ying Li,Chengcheng Liu,Jianqiu Zhang,Bo Hu,Dean Ta
DOI: https://doi.org/10.1109/ultsym.2019.8925690
2019-01-01
Abstract:Compared with X-ray tomography, the use of ultrasound provides the advantages of non-ionizing radiation and low cost. However, ultrasound imaging of cortical bone fracture is still challenging due to the significant velocity changes on the interface between the cortical bone (2800-4000 m/s) and soft tissue (1400-1700 m/s). Furthermore, the low contrast-to-noise ratio (CNR) caused by artifact affects the image quality. In this study, we apply a compressed sensing (CS) based three-layer velocity model for cortical bone fracture imaging. Multistatic synthetic aperture ultrasound (MSAU) was utilized to restrain the artifact and provide a high CNR. Synthetic aperture focusing technique (SAFT) was utilized as a comparison of MSAU. In vitro experiment was performed to validate the proposed method.
What problem does this paper attempt to address?