Sub-Nyquist Sampling Method and Its Application in High-Frequency Electric-Field Measurement

Hui Ding,Fangxing Lyu,Haichen Zhao,Xu Niu,Chunyang Han
DOI: https://doi.org/10.1117/1.oe.58.11.114106
IF: 1.3
2019-01-01
Optical Engineering
Abstract:A high-frequency signal sampling approach by combining with compressive sensing and random equivalent sampling technology is proposed. The proposed sampling method achieves similar to 10 times faster equivalent sampling rate by utilizing three parallel sub-Nyquist low-rate analog-to-digital converters (TPSL-ADC). By the union of the optical electric-field sensor with wide dynamic range and the proposed TPSL-ADC sampling method, a complete high-frequency electric-field signal measurement system has been realized. The high-frequency electric-field signal with an equivalent sampling rate of 1 GS/s is captured by utilizing three parallel ADCs with sampling rates of similar to 32.3, 31.3, and 30.3 MS/s, respectively. The effectiveness of the proposed electric-field sensing and detecting system has been experimentally demonstrated. (C) 2019 Society of Photo-Optical Instrumentation Engineers (SPIE)
What problem does this paper attempt to address?