[Efficacy of Sequential Correction Based on Satellite Rod Techniquein Degenerative Scoliosis with B-type Coronal Imbalance].

B L Shi,D Liu,S Q Xia,Y Li,B Shi,Z Liu,X Sun,Z,Y Qiu
DOI: https://doi.org/10.3760/cma.j.issn.0376-2491.2019.47.007
2019-01-01
Abstract:Objective: To evaluate the radiographic and clinical outcomes of sequential correction based on satellite rod technique in degenerative scoliosis (DS) with B-type coronal imbalance, and to investigate the efficacy of sequential correction in this cohort. Methods: Twenty-one DS patients with B-type coronal imbalance applying sequential correction from December 2015 to July 2017 in Nanjing Drum Tower Hospital were retrospectively reviewed. There were 4 males and 17 females in this group, the average age was (63±8) years. The coronal parameters including Cobb angle of main curve and distance between C(7) plumb line and center sacral vertical line (C(7)PL-CSVL), as well as sagittal parameters including global kyphosis (GK) and sagittal vertical axis (SVA) were assessed pre-operatively, post-operatively and at the last follow-up. The Scoliosis Research Society-22 (SRS-22) questionnaire was fulfilled before the operation and at each follow-up to evaluate the quality of life. Paired t test was performed for statistical analysis. Results: The patients were followed-up for (20±8) months. The post-operative Cobb angle of main curve was significantly improved from 52°±12° to 19°±7° (t=13.886, P<0.01), and it was 19°±8° at the last follow-up and no significant correction loss was attained (t=1.101, P=0.284). The values of C(7)PL-CSVL before the operation, after the operation and at the final follow-up were (46±11) mm, (12±7) mm and (12±7) mm, respectively; significant post-operative improvement achieved (t=19.718, P<0.01) while there was no correction loss at last follow-up (t=-1.393, P=0.179). After sequential correction, 20 patients (95.2%) improved to A-type coronal imbalance while 1 patient (4.8%) remained with B-type coronal imbalance. Significant post-operative improvements were found in terms of GK and SVA and no significant correction loss was found during follow-up. The scores of pain and self-image showed significant improvement at the last follow-up (t=8.706, 3.104, both P<0.01). In addition, there was no implant failure during follow-up. Conclusion: The sequential correction based on satellite rod technique in DS patients with B-type coronal imbalance corrects the deformity, relieves the clinical symptoms, improves the quality of life, and decreases the rates of post-operative coronal imbalance as well as implant-related complications.
What problem does this paper attempt to address?