Evaluation of Higher Order Aberrations and Anterior Segment Parameters Changes After Implantable Collamer Lens Implantation for High Myopia
Ghada A Nassar,Ezzat N Abbas,Mahmoud Mohammed Ahmed Ali Khalil,Ehab Tharwat,Ahmed R Mohammed
DOI: https://doi.org/10.2147/OPTH.S405182
2023-04-11
Clinical Ophthalmology
Abstract:Ghada A Nassar, 1 Ezzat N Abbas, 2 Mahmoud Mohammed Ahmed Ali Khalil, 2 Ehab Tharwat, 2 Ahmed R Mohammed 2 1 Department of Ophthalmology, Faculty of Medicine, Cairo University, Cairo, Egypt; 2 Department of Ophthalmology, Faculty of Medicine, Al-Azhar University, Cairo, Egypt Correspondence: Ghada A Nassar, 10 Said Street, Heliopolis, Cairo, 11757, Egypt, Tel +2 01222397300, Fax +20223636504, Email Purpose: To evaluate changes in higher order aberrations (HOAs) induced by implantable collamer lens (ICL) implantation in correction of high myopia and to compare the anterior segment parameters before and after surgery. Also, to correlate these parameters with HOAs, the best corrected visual acuity (BCVA) and intraocular pressure (IOP). Methods: This prospective interventional cohort case series study included 40 eyes with high myopia that underwent ICL V4c implantation. They were evaluated pre-operatively and post-operatively at 1 st and 3 rd month HOAs using Scheimpflug Sirius Camera. The anterior segment parameters were evaluated by optical biometry. Correlations between HOAs, BCVA and anterior segment parameters were evaluated. Results: The mean pre-operative BCVA was 0.67 ± 0.17, while post-operative BCVA was 0.74 ± 0.16 ( p -value < 0.001). The spherical equivalent was − 13.66 ± 2.23 pre-operatively, while post-operatively it was − 0.77 ± 0.65 ( p -value < 0.001). The mean pre-operative root mean square (RMS) of HOAs was 0.62 ± 0.11 μm, while mean post-operative RMS in the 1st month was 0.82 ± 0.29 μm ( p -value < 0.001). At 3rd month, it was 0.63 ± 0.17 μm ( p -value = 0.685). The mean pre-operative anterior chamber depth (ACD) was 3.66 ± 0.26 mm. It decreased in the post-operative 1 st month to 3.46 ± 0.30 mm, while in 3 rd month 3.45 ± 0.24 mm ( p -value < 0.001, < 0.001) respectively. The mean pre-operative anterior chamber angle (ACA) 45.98 ± 8.39 o while, the mean ACA was 31.65 ± 4.14, 31.03 ± 3.74 post-operatively ( p -value < 0.001, < 0.001) respectively. There was significant increase in IOP ( p -value < 0.001). Conclusion: ICL implantation is safe and effective in correction of high myopia, as HOAs increase at first month post-operatively then, return to the pre-operative level by 3 rd month. However, anterior segment parameters show significant changes which may need longer follow up. Keywords: implantable collamer lens, higher order aberrations, anterior segment parameters, Scheimpflug Sirius Camera, optical biometry, ICL, HOA Implantable collamer lens (ICL) has been documented to be safe and successful for correction of high myopia. ICL implantation has many benefits over corneal refractive surgeries such as laser in situ keratomileusis (LASIK) and photorefractive keratectomy (PRK). This is because ICL implantation avoids corneal complications, such as post LASIK ectasia and dry eye syndrome. ICLs also provide a wider range of refractive error correction. Furthermore, there are less possibilities of higher order aberrations (HOAs) in ICL implantation when compared to corneal refractive surgeries, as cornea is prolate in ICL implantation, but it changes to oblate after corneal surgery. Although different techniques in laser surgery and wave front optimized ablation, there are some factors which affect the outcome of laser surgery such as pre-operative HOAs, pupil size and cyclotorsional misaligned position of laser ablation. 1,2 A newly designed ICL with a 360 μm central hole in the central optical zone (V4C-ICL) avoids the need for peripheral iridotomy and decrease the incidence of complications such as anterior subcapsular cataract. The central hole is beneficial for the circulation of aqueous humor. However, HOAs may be created due to their optic properties and different corneal incisions of surgery. There are few studies which evaluated the effect of HOAs in V4C ICL implantation to assess their efficacy, safety and predictability after surgery. Their results revealed changes in HOAs with either positive or negative spherical aberrations. Moreover, visual disturbance, such as glare and halos were described early post-operatively. The effect of cylindrical wall of the central hole V4C-ICL may be added. It acts as an another optical surface, which may induces glare and halos. 3,4 Despite its safety, ICL implantation may still cause some complications such as endothelial cell loss, cataract and glaucoma. This is mainly secondary to under or oversizing of the lens. Therefore, the anterior segment parameters are valuable to avoid these complications. Central anterior chamber depth (ACD) an -Abstract Truncated-