Wide-band Phasor Measurement Unit: Design and Test

Chen Wu,Jie Sheng,Guangying Cheng,Ronghua Duan,Min Cheng,Xiaorong Xie,Zhixue Li
DOI: https://doi.org/10.1109/isgt-asia.2019.8881451
2019-01-01
Abstract:This paper presents the design of a wide-band phasor measurement unit (WPMU) that can capture both the fundamental component and each sub-/super- synchronous harmonic component of node current and node voltage. The work is concentrated on adopting the adaptive detection method to dynamically capture and filter harmonic wave within the frequency of 0-1550Hz. The proposed WPMU can be adopted in the monitoring, analyzing, controlling, and protecting of renewable highly integrated power systems where sub-synchronous resonance (SSR) occurs frequently. The adaptive detection principles are illustrated in detail and the accuracy, as well as the efficiency of the proposed equipment are tested and presented.
What problem does this paper attempt to address?