Temperature Control of PEMFC Based on Optimal Power Consumption

Su Zhou,Xuelei Zhi,Linjiong Yu
DOI: https://doi.org/10.23919/chicc.2019.8865220
2019-01-01
Abstract:Based on a45kW PEMFC engine, the cooling system is improved by including the intercooler into the cooling system and adding a coolant bypass valve. New temperature control strategy is developed for the improved cooling system with adoption of steady-state optimization control and feedback control, which not only keeping the stack temperature around the setting value, but also limiting the temperature difference between inlet coolant/air and stack into 10 °C, at the same time, power consumption of cooling system is lower. The strategy is validated by simulation tests in MATLAB/Simulink platform. Simulation results show that all the goals are reached with the application of new control strategy.
What problem does this paper attempt to address?