Full-scale Test of a Steel Moment-Resisting Frame with Composite Floor under a Penultimate Edge Column Removal Scenario

Junjie Wang,Wei Wang,Yihai Bao
DOI: https://doi.org/10.1016/j.jcsr.2019.105717
IF: 4.349
2019-01-01
Journal of Constructional Steel Research
Abstract:To investigate the load-resisting mechanisms and responses of typical steel-concrete composite frames under the progressive collapse scenario, a 2 x 1 bay full-scale steel-concrete composite floor system was quasi-statically tested till failure under a middle-edge column removal scenario. The test specimen was extracted from a prototype building, which was designed according to modern design codes. Based on the measured load-deflection response, load-carrying mechanisms, deformation patterns, and failure modes were discussed in detail. The maximum capacity was achieved at a chord rotation angle of 0.163 rad, where the steel girder and the composite slab contributed 19.2% and 80.8% of the total resistance, respectively. The peak resistant load, as a result of the combined catenary and tensile membrane action, is 15.9% higher than that of the flexural action alone. The load-carrying capacity of the test specimen is 5.5 times larger than the ASCE load combination for extraordinary events. The continuous steel deck and moment-resisting beam-column connections have a significant influence on the load-carrying capacity and the deformation capacity of the composite floor system. (C) 2020 American Society of Civil Engineers.
What problem does this paper attempt to address?