An Experimental Method to Measure Flow Distribution in the Cathode of HighâTemperature Polymer Electrolyte Membrane Fuel Cells Stack
Feng Ji,Linlin Yang,Yinhua Li,Hai Sun,Gongquan Sun
DOI: https://doi.org/10.1002/ente.201900416
IF: 4.149
2019-01-01
Energy Technology
Abstract:The flow distribution in manifolds has an important influence on the performance and life of the stack, but currently the methods to measure the cathode flow distribution between cells in a high-temperature polymer electrolyte membrane fuel cells (HT-PEMFC) stack is scarce. Herein, an experimental method for measuring the cathode flow distribution between cells is developed, which converts the cathode flow (Q) signal into a signal of hydrogen limiting current (i(L)). By dimensional analysis and experimental verification, it is found that i(L) and Q have a linear relationship within a certain range. In the HT-PEMFC single cell, the method can be used to quickly evaluate and screen the cathode diffusion layer. When used in the HT-PEMFC stack, the effect of temperature is negligible, but it is necessary to ensure the same compression ratio of each cell, whereas the i(L) of each cell is tested simultaneously in the stack. In addition, the method is limited to measure flow distribution between cells in the stack because the i(L) value is averaged.
What problem does this paper attempt to address?