Research on Droplet Entrainment in the Composite Quench Chamber

GUO Qiangqiang,WANG Yifei,PAN Fei,YAN Liucheng,ZHAO Hui,CHENG Mao
DOI: https://doi.org/10.13334/j.0258-8013.pcsee.2014.11.008
2014-01-01
Abstract:A cold mode experimental device was established for studying the droplet entrainment in the novel composite quench chamber. The effect of droplet entrainment on superficial gas velocity, nozzle flow velocity, cooling water flow and radial position was investigated. The experimental results show that droplet entrainment increases with the increase of superficial gas velocity and flow rate, while there has no significantly change in the radial direction of chamber. The droplet entrainment is decreased by about 40 percent when the number of nozzles increased from two to four. The increasing nozzle number can make the droplet well-distributed and reduce droplet entrainment. Meanwhile, an empirical correlation for droplet entrainment fraction and experimental parameters was also achieved .
What problem does this paper attempt to address?