Load allocation optimization during shutdown of combined-cycle units

Anping WAN,Jianhong CHEN,Deren SHENG,Xinjian GU,Yangjian JI,Jiongmin JIN
DOI: https://doi.org/10.16081/j.issn.1006-6047.2017.05.030
2017-01-01
Abstract:Aiming at the economic load allocation during the shutdown of combined-cycle units when the gas is not sufficient,an optimization model is established for the shutdown of combined-cycle units,which,based on the analysis of the comprehensive performance of each unit,optimally allocates the gas to each unit to achieve the maximum power generation and ensure the safe shutdown.A calculation program is developed for the shutdown optimization model.The calculative results of a power plant with three combined-cycle units show that,the variation of load-up rate has little effect on the total power generation while the variation of load-down rate has greater effect on the total power generation.When the residual gas is 105 m3,the total power generation of units with optimized shutdown scheme is 28.409 MW·h more than that with normal shutdown scheme,and the increased annual profit is 4.78692 million yuan.
What problem does this paper attempt to address?