Research on Electric Field Distribution of Roof Insulator Under Humid Condition and Its Improving Strategy

Song PENG,Guangning WU,Mengchun SHAO
DOI: https://doi.org/10.13296/j.1001-1609.hva.2017.08.019
2017-01-01
Abstract:Under humid condition,water droplets on the surface of roof insulator will lead electric filed distortion,and induce corona discharge,which is a threat to train operation.A roof insulator computational model is established based on finite element method to simulate the influence of water droplet parameters,like position,size and amount,on electric flied distribution along insulator surface.And grading ring frequently used on insulator for high voltage transmission line is applied to roof insulator,to suppress corona discharge induced by water droplet.Theresult shows,water droplet at the junction of shed and sheath has the greatest impact on electric field distortion.When the radius of water droplet is 2 mm,influence of water droplet on shed is most obvious.A larger distance between water droplets results in weaker maximum electric field along insulator surface.The optimal configuration scheme of grading ring is confirmed that radius is 85 mm,the section radius of grading ring is 24 mm,and the height apart from the high voltage side is 50 mm.