Highly Accurate Airflow Volumetric Flowmeters Via Pmuts Arrays Based on Transit Time

Xuying Chen,Chengwei Liu,Dengfei Yang,Xinxin Liu,Liang Hu,Jin Xie
DOI: https://doi.org/10.1109/jmems.2019.2916987
IF: 2.829
2019-01-01
Journal of Microelectromechanical Systems
Abstract:This paper describes a highly accurate airflow volumetric flowmeter using piezoelectric micromachined ultrasonic transducers (pMUTs) arrays based on transit time. Two pieces of 10by10 multipled aluminum nitride (AlN) pMUTs arrays at resonant frequency of 980 kHz are employed to transmit and receive ultrasonic signals alternately. The dimension of the fabricated 10by10 array is about 3.5 x 3.5 mm(2), so the pMUTs-based flowmeter is able to measure flow rate in a 3D-printed pipe with an inner diameter of 10 mm. An evaluation board TDC1000-TDC7200EVM with resolution in ns is used to excite the transducers and handle the received signal. Leveraging on the high signal to noise ratio (SNR, similar to 29 dB) of the pMUTs array and excellent resolution (ns) of the evaluation board, the flowmeter has high accuracy. For the reference volumetric flow rate varying from 0-9 L/min in the range of laminar flow, the relative errors of the correctional volumetric flow are within 3%.
What problem does this paper attempt to address?