Study on Dynamic Characteristics of a 600MW Ultra-Supercritical Double-Reheat Boiler

Zhu Wang,Ming Liu,Chaoyang Wang,Daotong Chong,Yunjie Yan
DOI: https://doi.org/10.1016/j.egypro.2019.01.653
2019-01-01
Energy Procedia
Abstract:Based on the GSE software, the simulation model of an ultra-supercritical double-reheat tower boiler was established, and its reliability was checked with design data. Then, the dynamic characteristics of the ultra-supercritical double-reheat boiler were studied. Simulation results reveal the response times of different input parameters greatly vary. When stepping disturbances to the feed-coal rate, feed-water rate, and feed-water temperature, the response time under feed-water’s temperature disturbance is the longest, which is about 1, 800 s. When the same input parameter disturbs, the output parameters have the same response tendency with different amplitudes. Moreover, the fiercer the disturbance is, the more greatly the parameter changes.
What problem does this paper attempt to address?