Accuracy Analysis of the Pointing and Focusing Calibration of the 5 M Terahertz Telescope for Dome A in Antarcticatwo

Kang Hao-ran,Zuo Ying-xi,Lou Zheng,He Qian-ru
DOI: https://doi.org/10.1016/j.chinastron.2019.02.004
2019-01-01
Chinese Astronomy and Astrophysics
Abstract:Pointing calibration and sub-reflector focusing are an important task of antenna measurement, which significantly contributes to the observational performance of a radio telescope. According to the requirements on the pointing accuracy and defocusing gain loss of the 5m Dome A Terahertz Explorer (DATE5), this paper has derived the requirements of signal-to-noise ratio for the pointing and sub-reflector focusing calibration observations, and selected several astronomical radio sources suitable for the pointing and focusing calibrations at the terahertz waveband in Antarctica, which include planets and ultra-compact HII regions. The effects of the atmospheric absorption and the source angular diameter on the accuracy of calibration measurements are analyzed. Simulations show that when the telescope operates in Antarctica, these sources can provide sufficient flux densities for verifying the pre-established pointing model and focusing model.
What problem does this paper attempt to address?