Effects of Pulse Length and Pulse Repetition Frequency on the Stable Cavitation Characteristics of Flowing Microbubbles

Mouwen Cheng,Fan Li,Tao Han,Alfred C. H. Yu,Peng Qin
DOI: https://doi.org/10.1109/ultsym.2018.8579793
2018-01-01
Abstract:Stable cavitation has shown great potential for clinical therapy. It is important to understand how the ultrasound pulse parameters affect the spatiotemporal distribution of stable cavitation energy. A tissue mimicking phantom for blood vessel was fabricated to comprehensively understand the effects of the pulse length (PL) and pulse repetition frequency (PRF) on stable cavitation characteristics of flowing microbubbles in the target area. A 1-MHz focused transducer and another 7.5-MHz plane transducer were employed to emit the pulsed ultrasound and receive the cavitation signal respectively. Then the signal was amplified and recorded by a high-speed AD. The following results were determined. Below the Critical PRF (CPRF), the PL had no influence on the temporal distribution of stable cavitation intensity; however, when PRF was above CPRF, the stable cavitation intensity had a uniform temporal distribution and was independent of the PRF at shorter PLs, The stable cavitation intensity correlated negatively with the PRF at longer PLs.