The effect of microbubbles on high intensity focused ultrasound focal region

Peng WANG,Mengjuan ZHAO,Shijing WU,Shihui CHANG,Xiqi JIAN
DOI: https://doi.org/10.11684/j.issn.1000-310X.2017.04.008
IF: 3.614
2017-01-01
Applied Acoustics
Abstract:The synergistic effect of microbubbles was used to enhance HIFU treatment focal region. However, the effect of microbubbles on HIFU focal region in different acoustic conditions during HIFU therapy is not clear. In this paper, the effect of power, exciting frequency, and initial bubble radius on the HIFU focal region in tissue mimicing phantom with microbubbles was discussed based on the acoustic propagation equation, Yang-Church bubble motion equation, bio-heat transfer equation, the finite difference time domain method and Runge-Kutta method, and tested by experiments of tissue mimicing phantom with SonoVue microbubbles. The results show that, as the input power, initial bubble radius and exciting frequency increasing, the size of focal region increases. As the input power increasing, the shape of focal region changes, as the initial bubble radius and the exciting frequency increasing, the focus moves away from the transducer side.
What problem does this paper attempt to address?