Trends of the Flow-Field Deflection and Asymmetric Combustion in a 600 MWe Supercritical Down-Fired Boiler with Respect to the Furnace Arch’s Burner Span

Min Kuang,Guohua Yang,Qunyi Zhu,Shuguang Ti
DOI: https://doi.org/10.1021/acs.energyfuels.7b01576
IF: 4.6541
2017-01-01
Energy & Fuels
Abstract:The asymmetric upper furnace configuration effect (mainly relied on the short upper furnace) and unreasonable burner designs (mainly related to the burner location and burner span on furnace arches) are taken as potential major factors favoring the asymmetric combustion formation in down-fired boilers. To confirm the burner span's role in this aspect, numerical simulations on coal combustion in a 600 MWe supercritical down-fired boiler that suffered from severe flow-field deflection and asymmetric combustion were carried out at three burner span settings (i.e., C-s = 0.387, 0.441, and 0.495), plus full-load industrial-size measurements at the boiler's design setup C-s = 0.441. The boiler's design setup shows a badly asymmetric combustion performance with poor burnout and high NOx emissions, corresponding to its severely deflected gas/particle flow field. Shortening the burner span to C-S = 0.387 greatly improves the flow-field deflection and asymmetric combustion, resulting in a burnout increase and NOx reduction. In contrast, expanding the burner span to C-s = 0.495 aggravates asymmetric combustion to gain a worsened furnace performance, with burnout loss and NOx emissions increased. These changes thus confirm the burner span as a major factor favoring asymmetric combustion. With a short upper furnace equipped to aggravate the asymmetric upper furnace configuration effect, a relatively smaller burner span such as C-s = 0.387 should be used for alleviating the flow-field deflection and asymmetric combustion if a high air-box pressure can be allowed in long-term operations.
What problem does this paper attempt to address?