Detection of the Chlamydia Trachomatis DNA by PCR-liquid Hybridization Method

李智涛,李振勇,杨国翠,冯艳铭,邵大晓,赵大鹏,崔天星,朱德华
DOI: https://doi.org/10.3969/j.issn.1671-6825.2002.01.015
2002-01-01
Abstract:Aim: To study the method of detecting chlamydia trachomatis (CT) DNA by PCR-liquid hybridization. Meth-ods: A total of 616 urogenital specimens from sexually transmitted disease (STD) clinics were subjected to CT DNA detection by PCR-liquid hybridization method, and the result was compared with that of the cell culture method. For the specimens which did not accord with culture result and the results were negative, the LCR method was applied. Results: PCR method had a higher specificity for detecting CT DNA, and could detect 0. 1 fg of CT DNA. The positivity rate (27.6%) of PCR was significantly higher than that of cell culture(6. 3% , P 0. 01) . When cell cultrue was used as the standard, the sensitivity of PCR was100% . Compared with LCR, the sensitivity and specificity of PCR method were 97.2% and 80.7% , respectively. Conclusion: PCR is a simple, sensitive, and specific method to detect CT DNA , and it is suitable for clinical use.
What problem does this paper attempt to address?