Abstract:In this study, a coordination imprinted polymer (CIP) solid-phase extraction (SPE) method was developed to determine the residues of flumequine (FLU) in fish samples. Silanized graphene oxide-doped CIP (SGO-CIP) monolithic column was prepared using FLU-Zn2+ as template in the presence of SGO. The synthesis conditions of SGO-CIP column were optimized by the response surface methodology. Under the optimum conditions, this column showed high specificity to FLU, and the adsorption capacity reached 61.74 ng mg(-1). The enrichment factor of the monolithic column was over 40-fold. Various factors affecting the extraction efficiency of SGO-CIP column during SPE were tested to achieve optimal enrichment and to reduce non-specific adsorption. FLU in fish was detected by using a high-performance liquid chromatography-fluorescence detection system. The detection limit was as low as 0.32 ng g(-1) and the recovery was as high as 95.2%, with relative standard deviations of below 5.9%. This simple and sensitive method may be applicable to the determination of FLU residues in foods.