An Improved Method for Modelling Coolant Radiolysis in ITER

Zhong Fang,Xuewu Cao,Lili Tong,Yusa Muroya,Giles Whitaker,Mojtaba Momeni,Mingzhang Lin
DOI: https://doi.org/10.1016/j.fusengdes.2017.12.031
IF: 1.905
2018-01-01
Fusion Engineering and Design
Abstract:Predicting the effects of coolant water radiolysis induced by neutron and gamma radiation in the International Thermonuclear Experimental Reactor (ITER) is important, as oxidizing species like O-2 and H2O2 will corrode structural materials, increasing maintenance costs and potentially compromising safety. In this work, a new model has been developed, by modifying existing models, to evaluate the water radiolysis behaviors in different Primary Heat Transfer Systems (PHTSs) in ITER. The new model takes the circulation of coolant, and the combined gamma and 14 MeV neutron radiation into consideration. We recommend injection of about 5 cc H-2 under standard temperature and pressure (STP) per kilogram of H2O into the First Wall/Blanket (FW/BLKT) PHTS to both efficiently suppress water radiolysis and avoid problems caused by addition of excessive H-2.
What problem does this paper attempt to address?