Measurement of Indoor Air Quality in Chinese Charcoal Barbecue Restaurants

Zhenhao Zhang,Yujiao Zhao,Min Zhou,Pengfei Tao,Ruoyao Li
DOI: https://doi.org/10.1016/j.proeng.2017.10.088
2017-01-01
Procedia Engineering
Abstract:An assessment of Chinese charcoal barbecue restaurants was carried out to assess the impact of ventilation systems on the indoor air quality. This study focused on the temperature field, relative humidity field and concentration distribution. The indoor environments of the sampled restaurants were related to the fuel of heat sources and the mechanical exhaust system, especially the local exhaust system. For most of time, CO2 values did not exceed the acceptable level. CO is the main contaminant of this kind of charcoal barbecue restaurants. From the data available we could find restaurant C3 produced the largest amount of CO (38.5 PPM) in cooking mode because of natural air supply. While restaurant C2 generated the largest amount of CO (42.6 PPM) in idle mode due to the temporary use of exhaust hood. There was a little difference between the mean temperatures and relative humidity before and after dinner.