Carbonaceous Particulate Matter Air Pollution and Human Exposure from Indoor Biomass Burning Practices

Junjun Zhong,Junnan Ding,Yuhong Su,Guofeng Shen,Yifeng Yang,Chen Wang,Staci L. Massey Simonich,Hongying Cao,Ying Zhu,Shu Tao
DOI: https://doi.org/10.1089/ees.2011.0543
IF: 2.1723
2012-01-01
Environmental Engineering Science
Abstract:Using both stationary air samplers and personal air samplers, concentrations of total suspended particulates, particulate matter with a diameter less than 2.5 mu m, elemental carbon, and organic carbon were measured in the kitchen, bedroom, and outdoors of a rural, nonsmoking household in northern China. The household used a traditional biomass cookstove in winter and summer and a more modern liquified petroleum gas cookstove on the first day in the summer. Most of the particulate matter concentrations both indoors and outdoors exceeded the national air quality standards of China (0.15 mg/m(3) for indoor particulate matter with a diameter of 10 mu m or less; 0.30 mg/m(3) for ambient air total suspended particulate). In the kitchen in the winter, the daily mean concentration of particulate matter with a diameter less than 2.5 mu m was 16 times larger than the national indoor air quality standard for particulate matter with a diameter of 10 mu m or less. On average, 53% of the total suspended particulate concentration was due to particulate matter with a diameter less than 2.5 mu m. While all of the residents of the household were exposed to high concentrations of particulate matter with a diameter less than 2.5 mu m, the housewife had the highest exposure. High daily variation in concentrations was due primarily to differences in fuel burning rates. Significant differences between kitchen/outdoor and bedroom/outdoor concentration ratios and between winter and summer indoor/outdoor concentration ratios suggested that bedroom particulate matter concentrations were due to emissions from the kitchen in winter and the outdoors in the summer. The average winter and summer elemental carbon/organic carbon concentration ratios were 0.20 +/- 0.14 (n = 24) and 0.32 +/- 0.16 (n = 18), respectively. In the bedroom and outdoors, the elemental carbon and organic carbon concentrations were correlated linearly with each other and with the concentration of particulate matter with a diameter less than 2.5 mu m. When only liquefied petroleum gas was used in the summer, the kitchen concentrations of particulate matter with a diameter less than 2.5 mu m and organic carbon were similar to or higher than the concentrations measured when the biomass burning stove was used.
What problem does this paper attempt to address?