Analysis of Flow Transition Effects on the Performances of a Wind Power Heat Pump System

Ming Zhao,Mingming Zhang,Jianzhong Xu
DOI: https://doi.org/10.1016/j.applthermaleng.2017.04.131
IF: 6.4
2017-01-01
Applied Thermal Engineering
Abstract:This paper proposes a detailed discussion on the influences of flow transition on heating capacity of wind power heat pump system based on a novel improved delayed detached eddy simulation (IDDES) method and thermodynamic analysis. A numerical study of DU-212 airfoil flow field at high Reynolds number (up to 1.5 x 10(7)) is first conducted. It is found that with high Reynolds number (Re = 1.5 x 10(7)), flow transition is remarkably promoted and lower aerodynamic drag is achieved due to the decrease of momentum loss. Then, the influences of leading-edge trip on aerodynamic performances are studied and corresponding physical mechanisms are revealed. Furthermore, the heating capacity of a two-stage heat pump system is evaluated based on thermodynamic analysis. It is found that enhanced flow transition associated with leading edge trip could account for a reduction of heating capacity to at most 21.8% under certain circumstances. Eventually, the influences of evaporation and condensation temperature are briefly studied. (C) 2017 Elsevier Ltd. All rights reserved.
What problem does this paper attempt to address?