Thermal Strain Measurement of East W/Cu Divertor Structure Using Electric Resistance Strain Gauges

Xingli Wang,Wanjing Wang,Jichao Wang,Ran Wei,Zhaoxuan Sun,Qiang Li,Chunyi Xie,Hong-En Chen,Kaiqiang Wang,Lei Wu,Zhenmao Chen,Guang-Nan Luo
DOI: https://doi.org/10.1016/j.fusengdes.2016.10.001
IF: 1.905
2016-01-01
Fusion Engineering and Design
Abstract:W/Cu divertor has complex structure and faces extreme work environment in EAST Tokamak device. To measure its thermal strain shall be a valued way to understand its service behavior and then optimize its design and manufacturing process. This work presents a preliminary study on measuring thermal strain of EAST W/Cu divertor structure using electric resistance strain gauges. Eight gauges had been used in the experiment and the heating temperature had been set to 230 degrees C with respect to the work temperature. To realize the measuring experiment, an appropriate fixing method of gauges in divertor narrow spaces had been taken and tested, which could not only withstand high temperature but also had no damage to the divertor sample. The measurement results were that three gauges showed positive strain while other three showed negative strain after having been compensated, which corresponded to tensile stress and compressed stress respectively. Two thermomechanical simulations had also been carried out and used for comparing with the experiment. (C) 2016 Elsevier B.V. All rights reserved.
What problem does this paper attempt to address?