Treatment of PTA Wastewater by Internal Circulation Anaerobic Reactor

黄玉,周兴求,牛晓君
DOI: https://doi.org/10.3969/j.issn.1009-2455.2009.01.021
2009-01-01
Abstract:The treatment of purified terephthalic acid (PTA) wastewater was investigated using an internal circulation anaerobic(IC) reactor at mid-temperature(35 ± 1) ℃. The results of the test showed that, under different HRT, the removal rate of COD maintained above 50%, the removal rate of TA was 43% - 82%, and there was a related change between the two. The sludge activity appeared very high and no apparent TA stagnation of degrada- tion emerged in the reactor. Along the height of the reactor, TA was absorbed firstly instead of degradation, and the results confirmed the existence of TA cumulation phenomenon. HRT had little influence on effluent VFA, the mass concentration of VFA varied from 117 mg / L to 396 mg / L, much less than 800 mg / L. The test results also indicated that, TA removal rate and effluent VFA was negatively correlated. The granular sludge index showed that, the sludge got a smaller size but more compact shape, the change of m(VSS) / m(SS) was little and the activity of the sludge was still high. The operating results verified the feasibility of using IC reactor as an effective apparatus in PTA wastewater treatment.
What problem does this paper attempt to address?