Study on Physical Measure of Seismic Intensity Based on Damage to Masonry Structures

HAO Min,XIE Lili,LI Wei
DOI: https://doi.org/10.3969/j.issn.1000-1301.2007.05.004
2007-01-01
Abstract:In order to study uhe physical measure of seismic intensity based on the damage to masonry structures,fifteen ground motion parameters were divided into 4 kinds according to their property and ground motion records were grouped into 3 teams based on three factors,that is amplitude,spectrum, and duration of ground motion.The correlation coefficient between the ductility of two masonry structures subjected to each group of ground motions and the corresponding ground motion parameters were calculated.Then the analysis and comparison of correlation coefficients were conducted and the result implied that PGA,EPA,Einput,Eh can reflect the damage potential for masonry structures.And all these ground motion parameters have good correlation with seismic intensity and they can serve as the physical measure of seismic intensity.
What problem does this paper attempt to address?