Transcatheter Closure of Membranous Ventricular Septal Defects with Home-Made Nitinol Occluder

秦永文,赵仙先,郑兴,丁继军,曹江
DOI: https://doi.org/10.3969/j.issn.1008-794x.2004.02.004
2004-01-01
Abstract:Objective To evaluate the feasibility and efficacy of transcatheter perimembranous ventricular septal defects (VSD) occlusion with home-made nitinol occluder.Methods Transcatheter closure was attempted in 196 patients with perimembranous VSD. The diameter of VSD measured by echocardiography was 3 to 15 mm, mean (4.94±2.23) mm. The angiographic diameter of the VSD was 3 to 6 mm, mean (3.92±1.44) mm. A 7-10F delivery sheath was advanced across the perimembranous VSD over a wire from femoral vein to deploy the occluder with the guidance of echocardiography and fluoroscopy. The device diameter selected was from 4 to 20 mm, mean (6.68±2.76) mm. Left ventriculography and transthoracic echocardiography were repeated to assess the closure of the defects 15 min after the procedure. Continuous electrocardiogram monitoring lasted for 5 days. The echocardiography and electrocardiogram examination were scheduled for 1, 6, and 12 months of follow-up. Results The occluders were successfully deployed in 191 patients. There were five procedural failures, two with device-related aortic insufficiency, and three of inability to pass through VSD. After deployment of the devices, there were no residual shunt in 180 of 191 patients, 11 patients with a trivial residual shunt that disappeared in 8 patients after one month of follow up. 3 patients developed mild tricuspid insufficiency. 12 developed transient complete right bundle branch block, and 5 transient complete left bundle branch block, and 2 transient complete atrioventricular block. There were repetitive nonparoxysmal ventricular tachycardia in 4 patients 1 week after the procedure. One patient had a detached device embolized into the left pulmonary artery but with a successful catheter retrieval by snare and transcatheter closure. The devices were similarly applied to patients with VSD associated with patent ductus arteriosus, and 4 patients with VSD complicated by atrial septal defects. The fluoroscopy time for the procedure was (13.2±7.7) min(range from 5 to 60 min). The procedure time was (59.5±18.2) min(range, 39 to 160 min). On follow-up evaluation of 1 month to 2 years, there were no episodes of endocarditis, thromboembolism and hemolysis. Conclusion Transcatheter closure of membranous ventricular septal defects with homemade nitinol occluder is effective, easy and safe.
What problem does this paper attempt to address?