Accurary of Titration Method for Detecting Live Attenuated Hepatitis A Vaccine

汪萱怡,徐志一,田美英,陈启明
DOI: https://doi.org/10.3969/j.issn.1004-5503.2001.03.014
2001-01-01
Abstract:Objective To increase the accuracy of titration method for detecting live attenuated hepatitis A vaccine. Methods The accuracy of various dosage groups,as well as various tubes in every group, were corn-pared. The TCID50 values calculated by modified Karber' s and Reed - Muench' s methods were also compared. Results Along with the decrease of dilution fold and/or the increase of tubes in each dilution,the stadnard error of TCID50 decreased. The 95% confidence interval of TCID50 calculated by modified Karber' s method was smaller than that by Reed - Muench' s method. Conclusion The accuracy can meet the requirements for the standard titration of live hepatitis A vaccine by decreasing dilution fold and increasing the tubes of each dilution at the same time.