Numerical Study of the Flow Field Inside a Combustion Chamber with Gas Film Cooling

SUN Xuewei,ZHU Keqin,XIN Wei,ZHAO Yue
DOI: https://doi.org/10.3321/j.issn:1000-0054.2008.08.030
2008-01-01
Abstract:The ablation of a combustion chamber cooled by a gas film was analyzed using numerical simulations of the flow field and temperature distributions inside the chamber.The results indicate that the cooling gas film is induced by a large eddy from the edge of the chamber towards the center.As a result,the temperatures rise to 2 252 K at the chamber throat,leading to the wall ablation.The throat temperature can be reduced by more than 500 K by changing the flow rate and direction of the cooling gas film to reduce the ablation.The gas film inflow angle for the highest cooling efficiency is 60°-70°.