Experimental study on three types of steel plate shear walls under cyclic loading

Yanlin GUO,Ming ZHOU,Quanli DONG,Xiaoan WANG
DOI: https://doi.org/10.14006/j.jzjgxb.2011.01.002
2011-01-01
Abstract:Buckling-restrained steel plate shear wall (BR-SPSW) has been proven to be an effective component for resisting lateral force and dissipating seismic energy. However, performances of moment-resisting frame structures with steel plate shear walls, especially the interactions between the walls and the frames remain to be investigated. An experimental study on a frame structure with BR-SPSW under cyclic loading was carried out, and as a contrast two more experiments on frame structures with non-stiffened and composite SPSW were conducted. A finite element analysis on the three SPSW specimens was made, and the differences between the three kinds of SPSWs were discussed. It is shown that frame structures with BR-SPSW have little buckling noise under lateral force, and possess better stiffness, larger ultimate loading capacity, better ductility and more stable hysteresis energy performance than frame structures with non-stiffened SPSW. With its yielding happens before buckling, the unfavorable effect on the adjacent columns induced by BR-SPSW is substantially lower than non-stiffened SPSW. Composite SPSWs have similar performances with BR-SPSWs, but after the covered concrete splits from the infill steel plate, tension field which brings additional moments to the frame columns appears in the steel plate, and ultimate load, stiffness and energy-dissipating ability of the wall all degenerate simultaneously.
What problem does this paper attempt to address?