Biomechanical Evaluation of Tendon Graft Fixation at the Tibial Site in Anteriorcruciate Ligament Reconstruction with Cortical Press-Fit Bolt

WANG Jun-liang,LIU Yu-jie,WANG Ai-yuan,LI Hai-feng,YANG Yu-ming,LI Zhong-li,WANG Zhi-gang
2009-01-01
Abstract:Objective To evaluate the biomechanical strength at the tibial site in anterior cruciate ligament(ACL)reconstruction with cortical press-fit bolt.Methods ACL was reconstructed in 21 fresh frozen cadaver knees using four-stranded hamstring tendon graft.Specimens were divided into cortical press-fit bolt group(n=7),bioabsorbable interference screw group(n=7),and intrafix group(n=7).On each sample,a load-to-failure test was performed.Ultimate failure load,stiffness,displacement of 100N and 400N, and mode of failure were recorded.Results The failure load and stiffness of cortical press-fit bolt fixation were lower than those of intrafix fixation(P0.05).Displacement of 100N and 400N of cortical press-fit bolt fixation was higher than that of intrafix fixation (P0.05).No statistical difference was found in cortical press-fit bolt fixation and bioabsorbable interference screw fixation(P0.05). Conclusion The biomechanical strength of tendon graft fixation at the tibial site with cortical press-fit bolt and bioabsorbable interference screw is similar,and can meet the physiological demand of tendon graft fixation in ACL reconstruction.
What problem does this paper attempt to address?