A Study on the Relationship Between EPS and Sludge Activity in MBR

王宏杰,王雪芹,李绍峰
DOI: https://doi.org/10.3969/j.issn.1007-2284.2007.12.018
2007-01-01
Abstract:The COD degradation kinetics equation was established by Eckenfelder model to characterize the sludge activity in MBR,and the COD degradation rates at SRT=19 d,27 d,34 d,43 d,50 d,59 d,67 d and 76d were determined.The experiment results indicated that the sludge activity ascended firstly and then descended along with the operation time while the COD removal rate K1 at SRT=50 d was 2.72 when it reached the vertex.The variation tendency of EPS concentration and sludge activity along with the SRT was consistent quite well and the EPS concentration reached 252.08 mg/L when the SRT was 43d.The correlation of EPS and COD degradation rate K1 was y = 42.553 K1+141,which suggested the higher the EPS concentration,the more rapidly the COD was degraded and the more active was the sludge.