Mechanism and Control of High Sulfide Sludge Bulking

Hua-shan HUANG,Pei-shi QI,Lei DING,Yun-zhi LIU
DOI: https://doi.org/10.3321/j.issn:1000-4602.2008.05.016
2008-01-01
Abstract:The cause of sulfide sludge bulking produced by high concentration industrial waste-water with sulfate in aerobic aeration tank was analyzed.The high sulfide sludge bulking was controlled using DO-pH control method in hybrid bioreactor.The results show that it is an economical and effective way to control sulfide sludge bulking by adjusting pH value in influent.Under anoxic condition,the SVI value in effluent is reduced from 834 mL/g to 200 mL/g when the pH value in the influent is increased to 7.5.Under micro-aerobic condition,the SVI value in effluent is quickly reduced to less than 100 mL/g if the DO is adjusted to 0.7-1.0 mg/L in the bio-selector and the pH value maintains at 7.5.
What problem does this paper attempt to address?