Elastic-plastic Analysic of Short-leg Shear Wall Structure with Simulative Static Test

WANG Jian-xiang,HU Jing-long,SU Fang,LI Qing-ning,YU Jian-jun
DOI: https://doi.org/10.3969/j.issn.1007-8614.2006.01.019
2006-01-01
Abstract:Simulative analysis on short-leg shear wall was conducted using the general FEA program ANSYS,and the whole process from concrete elastic to plastic until crush was revealed.Some factors which may influent its load-carrying and deformation capacity such as sectional depth-thickness ratio,concrete strength-grade, span-depth ratio of couple beam,ratio of axial compressive force to ultimate capacity were discussed.The result revealed that when the sectional depth-thickness ratio was 6.5,the load-carrying and deformation capacity were relatively high.Couple beam yielded before the leg.
What problem does this paper attempt to address?