Modeling on Temperature Field of Arch Crown in Long Tunnel Fires

Ya-dong HUANG,Ke WU,Zhi-yi HUANG,Jin-chang WANG
DOI: https://doi.org/10.3969/j.issn.1009-0029.2009.04.004
2009-01-01
Fire Science and Technology
Abstract:A temperature field simulation of arch crown in long tunnel fires,under different fire loads and ventilation velocity,was carried out,employing non-premixed combustion model which considered turbulence effect and radiation.Furthermore,the temperature distribution of arch crown and the corresponding changes caused by different fire loads and ventilation velocity during tunnel fires were analyzed.The results indicate that,taking 300 ℃ as critical temperature,the structure of arch crown won't be damaged when the fire load is lower than 10 MW;and this can also be insured when the fire load is 20 MW、50 MW,as long as the ventilation velocity is kept at 2.0 m/s、4.0 m/s respectively.It can also be concluded that increasing the ventilation velocity can improve the heat dissipation and meanwhile,reinforce the convection of high temperature smoke and extend the temperature rising area of arch crown,which may consequently induce an even larger range of damaged arch crown's structure after the fire lasting for some time.
What problem does this paper attempt to address?